2.7.4

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

93

battery.charge.low

10

battery.charge.warning

50

battery.mfr.date

2022/10/25

battery.runtime

65535

battery.runtime.low

1200

battery.temperature

16.6

battery.type

PbAc

battery.voltage

52.4

battery.voltage.nominal

48.0

device.mfr

American Power Conversion

device.model

Smart-UPS 2200

device.serial

AS1250244567

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

10

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.synchronous

no

driver.version

2.7.4

driver.version.data

APC HID 0.96

driver.version.internal

0.41

input.sensitivity

medium

input.transfer.high

253

input.transfer.low

200

input.voltage

0.0

output.current

0.50

output.frequency

50.0

output.voltage

220.4

output.voltage.nominal

220.0

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.delay.start

30

ups.firmware

654.19.I

ups.firmware.aux

7.4

ups.load

5.2

ups.mfr

American Power Conversion

ups.mfr.date

2012/12/11

ups.model

Smart-UPS 2200

ups.productid

0002

ups.serial

AS1250244567

ups.status

OB DISCHRG

ups.test.result

No test initiated

ups.timer.reboot

-1

ups.timer.shutdown

-1

ups.timer.start

-1

ups.vendorid

051d

About this device

Reported at:

Further system data or configuration example:

Data sample
The Battery Runtime data does not match the data from the APC UPS.
This looks like some kind of variable limitation, since the `upsc`
shows `65535`, which is equal to 18 hours 12 minutes and 15 seconds.
But in fact, the APC UPS shows the remaining time as 34 hours 1 min.

Packaged "nut is already the newest version (2.7.4-13)".

2.2.0

Report #1 with driver apcsmart (detailed comments available)

This device is known to work with driver apcsmart.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.alarm.threshold

0

battery.charge

089.0

battery.charge.restart

00

battery.date

01/10/04

battery.packs

000

battery.runtime

21180

battery.runtime.low

120

battery.voltage

52.95

battery.voltage.nominal

048

driver.name

apcsmart

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ttyS0

driver.version

2.2.0-

driver.version.internal

1.99.8

input.frequency

50.00

input.quality

00

input.sensitivity

H

input.transfer.high

253

input.transfer.low

196

input.transfer.reason

T

input.voltage

000.0

input.voltage.maximum

000.0

input.voltage.minimum

000.0

output.voltage

228.1

output.voltage.nominal

230

ups.delay.shutdown

020

ups.delay.start

000

ups.firmware

80.14.I

ups.id

UPS_IDEN

ups.load

000.0

ups.mfr

APC

ups.mfr.date

01/10/04

ups.model

SMART-UPS 2200

ups.serial

YS0402211565

ups.status

OB

ups.temperature

024.7

ups.test.interval

1209600

ups.test.result

NO