Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from REDi.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.6.3

Report #1 with driver blazer_ser (detailed comments available)

This device is known to work with driver blazer_ser. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.voltage

13.60

battery.voltage.nominal

12.0

beeper.status

enabled

device.type

ups

driver.name

blazer_ser

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ttyS0

driver.version

2.6.3

driver.version.internal

1.51

input.current.nominal

2.0

input.frequency

50.1

input.frequency.nominal

50

input.voltage

236.7

input.voltage.fault

236.7

input.voltage.nominal

230

output.voltage

236.7

ups.delay.shutdown

30

ups.delay.start

180

ups.load

14

ups.status

OL

ups.temperature

25.0

ups.type

offline / line interactive

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.toggle

  • load.off

  • load.on

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop

Report #2 with driver blazer_ser (detailed comments available)

This device is known to work with driver blazer_ser. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.voltage

13.60

battery.voltage.nominal

12.0

beeper.status

enabled

device.type

ups

driver.name

blazer_ser

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ttyS0

driver.version

2.6.3

driver.version.internal

1.51

input.current.nominal

2.0

input.frequency

49.9

input.frequency.nominal

50

input.voltage

238.7

input.voltage.fault

238.7

input.voltage.nominal

230

output.voltage

238.7

ups.delay.shutdown

30

ups.delay.start

180

ups.load

17

ups.status

OL

ups.temperature

25.0

ups.type

offline / line interactive

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.toggle

  • load.off

  • load.on

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop