# DEVICE:URL:REPORT: https://github.com/networkupstools/nut/issues/1279 # DEVICE:COMMENT: # Online Xanto S700 (build before 2012). But now it almost works, # except parameter 'override.battery.packs' doesn't work. # # Incorrect battery voltage is still reported (similar issue # with some other Qx devices is tracked). # # The batteries' voltage is 2.27V. So I hoped the parameter # 'override.battery.packs=12' will help. But it doesn't work. # The reported voltage is still 2.27V. # DEVICE:EOC # DEVICE:COMMENT-BLOCK:UPSCONF: # [ups] # driver = nutdrv_qx # port = "/dev/ttyUSB0" # desc = "Online Xanto S700" # protocol = q1 # override.battery.packs = 12 # default.battery.voltage.nominal = 24.00 # default.battery.voltage.low = 22.00 # default.battery.voltage.high = 26.00 # runtimecal = 240,100,720,50 # chargetime = 43200 # idleload = 10 # pollfreq = 5 # default.ups.mfr = "Online-UPS" # default.ups.model = "Xanto S700" # DEVICE:EOC # :; upsc battery.charge: 100 battery.packs: 12 battery.runtime: 2400 battery.voltage: 2.27 battery.voltage.high: 26.00 battery.voltage.low: 22.00 battery.voltage.nominal: 24.00 device.mfr: Online-UPS device.model: Xanto S700 device.type: ups driver.name: nutdrv_qx driver.parameter.chargetime: 43200 driver.parameter.idleload: 10 driver.parameter.pollfreq: 5 driver.parameter.pollinterval: 2 driver.parameter.port: /dev/ttyUSB0 driver.parameter.protocol: q1 driver.parameter.runtimecal: 240,100,720,50 driver.parameter.synchronous: no driver.version: 2.7.4 driver.version.data: Q1 0.07 driver.version.internal: 0.28 input.frequency: 50.0 input.voltage: 243.8 input.voltage.fault: 243.8 output.voltage: 230.0 ups.beeper.status: disabled ups.delay.shutdown: 30 ups.delay.start: 180 ups.load: 0 ups.mfr: Online-UPS ups.model: Xanto S700 ups.status: OL ups.temperature: 25.0 ups.type: online