# DEVICE:URL:REPORT: https://github.com/networkupstools/nut/issues/483#issuecomment-590977267 # DEVICE:COMMENT: # Without the `overrides` and `ignorelb` posted in the `ups.conf` snippet, # the UPS not reporting Low Battery for some reason (tried running on battery # till the 1% `battery.charge`). # # Charging status and `battery.voltage` is missing too (but they are present # with Phoenixtec/Liebert HID 0.3), as you can see. The `ups.power.nominal` and # `ups.realpower` values also looks strange. # DEVICE:EOC # DEVICE:COMMENT-BLOCK:UPSCONF: # [pw] # driver = usbhid-ups # desc = "PowerWalker VI 650 SH" # port = auto # ignorelb # override.battery.charge.warning = 30 # override.battery.charge.low = 15 # override.battery.runtime.low = 180 # override.ups.model = "PowerWalker VI 650 SH" # DEVICE:EOC # :; upsc pw battery.charge: 20 battery.charge.low: 15 battery.charge.warning: 30 battery.runtime: 274 battery.runtime.low: 180 battery.type: PbAc device.mfr: PPC device.model: PowerWalker VI 650 SH device.serial: 000000000 device.type: ups driver.flag.ignorelb: enabled driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.synchronous: no driver.version: 2.7.4-738-ge27f1f90 driver.version.data: MGE HID 1.44 driver.version.internal: 0.43 input.voltage: 236.0 outlet.1.status: on output.frequency: 50.3 output.frequency.nominal: 50 output.voltage: 236.0 output.voltage.nominal: 230 ups.beeper.status: enabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.load: 24 ups.mfr: PPC ups.model: PowerWalker VI 650 SH ups.power.nominal: 2 ups.productid: ffff ups.realpower: 0 ups.serial: 000000000 ups.status: OL ups.test.result: No test initiated ups.timer.shutdown: 0 ups.timer.start: 0 ups.type: offline / line interactive ups.vendorid: 06da # DEVICE:COMMENT-BLOCK:FIXME:UPSCMD: pw # Instant commands supported on UPS [pw]: # beeper.disable - Disable the UPS beeper # beeper.enable - Enable the UPS beeper # beeper.mute - Temporarily mute the UPS beeper # beeper.off - Obsolete (use beeper.disable or beeper.mute) # beeper.on - Obsolete (use beeper.enable) # load.off - Turn off the load immediately # load.off.delay - Turn off the load with a delay (seconds) # load.on - Turn on the load immediately # load.on.delay - Turn on the load with a delay (seconds) # shutdown.return - Turn off the load and return when power is back # shutdown.stayoff - Turn off the load and remain off # shutdown.stop - Stop a shutdown in progress # test.battery.start.deep - Start a deep battery test # test.battery.start.quick - Start a quick battery test # test.battery.stop - Stop the battery test # DEVICE:EOC # DEVICE:COMMENT-BLOCK:FIXME:UPSRW: pw # [output.voltage.nominal] # Nominal output voltage (V) # Type: ENUM # Option: "200" # Option: "208" # Option: "220" # Option: "230" SELECTED # Option: "240" # # [ups.delay.shutdown] # Interval to wait after shutdown with delay command (seconds) # Type: STRING # Maximum length: 10 # Value: 20 # # [ups.delay.start] # Interval to wait before (re)starting the load (seconds) # Type: STRING # Maximum length: 10 # Value: 30 # DEVICE:EOC