Report #1 with driver nutdrv_qx (detailed comments available)

This device is known to work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.capacity.nominal

18.0

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.packs

2

battery.runtime

4468

battery.type

PbAcid

battery.voltage

27.40

battery.voltage.high

25.00

battery.voltage.low

21.00

battery.voltage.nominal

24

device.mfr

Green Cell

device.model

PowerProof 2000VA UPS05

device.type

ups

driver.name

nutdrv_qx

driver.parameter.chargetime

28800

driver.parameter.idleload

4

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.protocol

q1

driver.parameter.runtimecal

2340,8,4740,4

driver.parameter.synchronous

auto

driver.version

2.8.0

driver.version.data

Q1 0.07

driver.version.internal

0.32

driver.version.usb

libusb-1.0.26 (API: 0x1000109)

input.frequency

50.1

input.frequency.nominal

50.0

input.voltage

238.7

input.voltage.fault

238.7

input.voltage.nominal

230.0

output.current.nominal

8.0

output.frequency.nominal

50.0

output.voltage

239.2

output.voltage.nominal

230.0

ups.beeper.status

enabled

ups.delay.shutdown

30

ups.delay.start

180

ups.load

3

ups.mfr

Green Cell

ups.mfr.date

2024/12/17

ups.model

PowerProof 2000VA UPS05

ups.power.nominal

2000

ups.product

MEC0003

ups.productid

0000

ups.realpower.nominal

1200

ups.status

OL

ups.type

offline / line interactive

ups.vendor

Fry's Electronics

ups.vendorid

0001

About this device

The UPS looks to be working with the nutdrv_qx driver, different status events are properly reported.

The (v2.8.0) nut-scanner tool suggested nutdrv_qx driver according to vendorid/productid which is used in many unrelated devices, that driver supports the (Qx) protocol here.

Reported at:

Further system data or configuration example:

Driver configuration
maxretry = 1
pollinterval = 2
battery_voltage_reports_one_pack

[gc2000va]
  driver = nutdrv_qx
  protocol = q1
  port = auto
  desc = "Green Cell PowerProof 2000VA UPS05"
  chargetime = 28800
  idleload = 4
  default.battery.type = PbAcid
  default.battery.capacity.nominal = 18.0
  default.battery.charge.low = 10
  default.battery.charge.warning = 50
  default.battery.voltage.nominal = 24
  default.battery.voltage.low = 21.00
  default.battery.voltage.high = 25.00
  default.battery.packs = 2
  runtimecal = 2340,8,4740,4
  default.input.frequency.nominal= 50.0
  default.input.voltage.nominal= 230.0
  default.output.current.nominal = 8.0
  default.output.frequency.nominal = 50.0
  default.output.voltage.nominal = 230.0
  default.ups.mfr = "Green Cell"
  default.ups.model = "PowerProof 2000VA UPS05"
  default.ups.mfr.date = "2024/12/17"
  default.ups.vendor = "Fry's Electronics"
  default.ups.product = "MEC0003"
  default.ups.power.nominal = "2000"
  default.ups.realpower.nominal = "1200"