NAME
richcomm_usb - Driver UPS equipment using Richcomm dry-contact to USB solution
NOTE ABOUT HISTORIC NUT RELEASE
Note
|
Two NUT websites
This version of the page reflects NUT release v2.8.1 with codebase commited 4ba352d8f at 2023-10-31T21:46:20+01:00 Options, features and capabilities in current development (and future releases) are detailed on the main site and may differ from ones described here. |
NOTE
This man page only documents the specific features of the richcomm_usb driver. For information about the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE
The Richcomm dry-contact to USB solution is a generic interface that is used to upgrade an existing (RS-232) contact closure UPS interface to USB. As such, all the limitations of the underlying contact closure interface apply. This means that you will only get the essentials in ups.status: OL, OB, and LB. See also genericups(8).
BUGS
Most contact-closure UPSes will not power down the load if the line power is present. This can create a race when using secondary upsmon(8) systems. See the upsmon(8) man page for more information.
The solution to both of these problems is to upgrade to a smart protocol UPS of some kind that allows detection and proper load cycling on command.
AUTHORS
-
Peter van Valderen <p.v.valderen at probu.nl>
-
Dirk Teurlings <dirk at upexia.nl>
SEE ALSO
The core driver:
The generic serial driver:
Internet resources:
The NUT (Network UPS Tools) home page: https://www.networkupstools.org/