SUPPORTED HARDWARE
usbhid-ups brings USB/HID UPS monitoring to NUT on all platforms supporting USB through libusb. It should detect any UPS that uses the HID Power Device Class, but the amount of data will vary depending on the manufacturer and model.
At the present time, usbhid-ups supports:
-
the newer Eaton USB models,
-
all MGE USB models,
-
all Dell USB models,
-
all AMETEK Powervar UPM models,
-
some APC models,
-
some Belkin models,
-
some Cyber Power Systems models,
-
some Powercom models,
-
some PowerWalker models,
-
some TrippLite models.
For a more complete list, refer to the NUT hardware compatibility list, available in the source distribution as data/driver.list, or on the NUT website. You may use the "explore" driver option to gather information from HID UPSes which are not yet supported; see below for details.
This driver is known to work on:
-
most Linux systems,
-
FreeBSD (beta stage) and maybe other *BSD,
-
Darwin / Mac OS X,
-
Solaris 10 and illumos-based distributions.
EXTRA ARGUMENTS
This driver also supports the following optional settings:
- port = string
-
Some value must be set, typically auto.
NoteThis could be a device filesystem path like /dev/usb/hiddev0
but current use of libusb API precludes knowing and matching by such identifiers. They may also be inherently unreliable (dependent on re-plugging and enumeration order). At this time the actual value is ignored, but syntactically some port configuration must still be there.
It is possible to control multiple UPS units simultaneously by running several instances of this driver, provided they can be uniquely distinguished by setting some combination of the vendor, product, vendorid, productid, serial, bus and/or device options detailed below. For devices or operating systems that do not provide sufficient information, the allow_duplicates option can be of use (limited and risky!)
- vendorid = regex
- productid = regex
- vendor = regex
- product = regex
- serial = regex
-
Select a specific UPS, in case there is more than one connected via USB. Each option specifies an extended regular expression (see regex(7) for more information on regular expressions), which must match the UPS’s entire respective vendor/product/serial string (minus any surrounding whitespace), or the whole 4-digit hexadecimal code for
vendorid
andproductid
.Try lsusb(8) or running this NUT driver with -DD command-line argument for finding out the strings to match.
Examples:
-
-x vendor="Foo.Corporation.*"
-
-x vendorid="051d*"
(APC) -
-x product=".*(Smart|Back)-?UPS.*"
-
- bus = regex
-
Select a UPS on a specific USB bus or group of buses. The argument is a regular expression that must match the bus name where the UPS is connected (e.g.
bus="002"
orbus="00[2-3]"
) as seen on Linux in/sys/bus/usb/devices
or lsusb(8); including leading zeroes. - device = regex
-
Select a UPS on a specific USB device or group of devices. The argument is a regular expression that must match the device name where the UPS is connected (e.g.
device="001"
ordevice="00[1-2]"
) as seen on Linux in/sys/bus/usb/devices
or lsusb(8); including leading zeroes.Notedevice numbers are not guaranteed by the OS to be stable across re-boots or device re-plugging. - busport = regex
-
If supported by the hardware, OS and libusb on the particular deployment, this option should allow to specify physical port numbers on an USB hub, rather than logical
device
enumeration values, and in turn — this should be less volatile across reboots or re-plugging. The value may be seen in the USB topology output oflsusb -tv
on systems with that tool, for example.Notethis option is not practically supported by some NUT builds (it should be ignored with a warning then), and not by all systems that NUT can run on. - allow_duplicates
-
If you have several UPS devices which may not be uniquely identified by the options above (e.g. only VID:PID can be discovered there), this flag allows each driver instance where it is set to take the first match if available, or proceed to try another.
Normally the driver initialization would abort at this point claiming "Resource busy" or similar error, assuming that the otherwise properly matched device is unique — and some other process already handles it.
Warning
Note
|
Two NUT websites This version of the page reflects NUT release v2.8.1
with codebase commited 4ba352d8f at 2023-10-31T21:46:20+01:00 |
Options, features and capabilities in current development (and future releases) are detailed on the main site and may differ from ones described here.
This feature is inherently non-deterministic! The association of driver instance name to actual device may vary between runs!
If you only care to know that at least one of your no-name UPSes is online, this option can help.
If you must really know which one, it will not!
- usb_set_altinterface = bAlternateSetting
-
Force redundant call to
usb_set_altinterface()
, especially if needed for devices serving multiple USB roles where the UPS is not represented by the interface number0
(default). - subdriver=regex
-
Select the USB HID subdriver for the device manually, where automatic match by device attributes alone does not suffice (e.g. new devices for which no
vendorid
/productid
pair was built into any driver — but common USB HID support is anticipated, or for different-capability devices with same interface chips, notably "phoenixtec/liebert" and "mge").Run the driver program with the
--help
option to see the exact list ofsubdriver
values it would currently recognize.Notethis option first checks for exact matches to subdriver identification strings, such as "TrippLite HID 0.85"
(which are prone to bit-rot), and if there was no exact match — retries with a case-insensitive extended regular expression.NoteWhen using this option, it is mandatory to also specify the vendorid and productid matching parameters. - offdelay=num
-
Set the timer before the UPS is turned off after the kill power command is sent (via the -k switch).
The default value is 20 (in seconds). Usually this must be lower than ondelay, but the driver will not warn you upon startup if it isn’t.
Note that many Cyber Power Systems (CPS) models tend to divide this delay by 60 and round down, so the minimum advisable value is 60 to avoid powering off immediately after NUT sends the shutdown command to the UPS.
- ondelay=num
-
Set the timer for the UPS to switch on in case the power returns after the kill power command had been sent, but before the actual switch off. This ensures the machines connected to the UPS are, in all cases, rebooted after a power failure.
The default value is 30 (in seconds). Usually this must be greater than offdelay, but the driver will not warn you upon startup if it isn’t. Some UPSes will restart no matter what, even if the power is (still) out at the moment this timer elapses. In that case, you could see whether setting
ondelay = -1
in ups.conf helps.Note that many CPS models tend to divide this delay by 60 and round down, so the minimum advisable value is 120 to allow a short delay between when the UPS shuts down, and when the power returns.
- pollfreq=num
-
Set polling frequency for full updates, in seconds. Compared to the quick updates performed every "pollinterval" (the latter option is described in ups.conf(5)), the "pollfreq" interval is for polling the less-critical variables. The default value is 30 (in seconds).
- pollonly
-
If this flag is set, the driver will not use Interrupt In transfers during the shorter "pollinterval" cycles (not recommended, but needed if these reports are broken on your UPS).
- onlinedischarge
-
If this flag is set, the driver will treat
OL+DISCHRG
status as offline. For most devices this combination means calibration or similar maintenance; however some UPS models (e.g. CyberPower UT series) emitOL+DISCHRG
when wall power is lost — and need this option to handle shutdowns. - onlinedischarge_calibration
-
If this flag is set, the driver will treat
OL+DISCHRG
status as calibration. Some UPS models (e.g. APC were seen to do so) reportOL+DISCHRG
when they are in calibration mode. This usually happens after a few seconds reporting anOFF
state as well, while the hardware is switching to on-battery mode.NoteIf it takes so long on your device that a shutdown gets issued, you may want to look at upsmon
optionOFFDURATION
used to filter out temporary values of "administrative OFF" as not a loss of a feed for the powered load. - disable_fix_report_desc
-
Set to disable fix-ups for broken USB encoding, etc. which we apply by default on certain models (vendors/products) which were reported as not following the protocol strictly. This flag allows to disable the feature in particular device configurations.
It is always possible that the vendors eventually release fixed firmware, or re-use identifiers by which we match suspected broken devices for unrelated products, so processing these fix-ups would be a waste of time there.
It is also always possible that NUT fix-ups cause issues on some devices, whether due to NUT bugs or because the vendor protocol implementation is broken in more than one place.
- explore
-
With this option, the driver will connect to any device, including ones that are not yet supported. This must always be combined with the "vendorid" option. In this mode, the driver will not do anything useful except for printing debugging information (typically used with -DD).
- maxreport
-
With this option, the driver activates a tweak to workaround buggy firmware returning invalid HID report length. Some APC Back-UPS units are known to have this bug.
- interruptonly
-
If this flag is set, the driver will not poll UPS. This also implies using of INPUT flagged objects. Some Powercom units need this option.
- interruptsize=num
-
Limit the number of bytes to read from interrupt pipe. For some Powercom units this option should be equal to 8.
- waitbeforereconnect=num
-
The driver automatically tries to reconnect to the UPS on unexpected error. This parameter (in seconds) allows it to wait before attempting the reconnection. The default value is 0.
Notefor instance, it was found that Eaton MGE Ellipse Max 1500 FR UPS firmware stops responding every few hours, which causes usbhid-ups driver to detect an libusb insufficient memory error; in this case, when the usbhid-ups driver tries to reconnect too early, the activity sometimes led the UPS firmware to crash and turn off the load immediately! Setting this parameter to 30 seconds solved this problem (while 20 seconds were not enough).
INSTALLATION
This driver is not built by default. You can build it by using "configure --with-usb=yes". Note that it will also install other USB drivers.
You also need to install manually the legacy hotplug files (libhidups and libhid.usermap, generally in /etc/hotplug/usb/), or the udev file (nut-usbups.rules, generally in /etc/udev/rules.d/) to address the permission settings problem. For more information, refer to the README file in nut/scripts/hotplug or nut/scripts/udev.
IMPLEMENTATION
Selecting a specific UPS
As mentioned above, the driver ignores the "port" value in ups.conf. Unlike previous versions of this driver, it is now possible to control multiple UPS units simultaneously with this driver, provided they can be distinguished by setting some combination of the device-matching options. For instance:
[mge]
driver = usbhid-ups
port = auto
vendorid = 0463
[tripplite]
driver = usbhid-ups
port = auto
vendorid = 09ae
USB Polling and Interrupt Transfers
The usbhid-ups driver has two polling intervals. The "pollinterval" configuration option controls what can be considered the "inner loop", where the driver polls and waits briefly for "interrupt" reports. The "pollfreq" option is for less frequent updates of a larger set of values, and as such, we recommend setting that interval to several times the value of "pollinterval".
Many UPSes will respond to a USB Interrupt In transfer with HID reports
corresponding to values which have changed. This saves the driver from having
to poll each value individually with USB Control transfers. Since the OB
and
LB
status flags are important for a clean shutdown, the driver also
explicitly polls the HID paths corresponding to those status bits during the
inner "pollinterval" time period. The "pollonly" option can be used to skip
the Interrupt In transfers if they are known not to work.
KNOWN ISSUES AND BUGS
Repetitive timeout and staleness
Some models tends to be unresponsive with the default polling frequency. The result is that your system log will have lots of messages like:
usb 2-1: control timeout on ep0in
usb 2-1: usbfs: USBDEVFS_CONTROL failed cmd usbhid-ups rqt 128 rq 6 len 256
ret -110
In this case, simply modify the general parameter "pollinterval" to a higher value (such as 10 seconds). This should solve the issue.
Note that if you increase "pollinterval" beyond 10 or 15 seconds, you might also want to increase "pollfreq" by the same factor.
Got EPERM: Operation not permitted upon driver startup
You have forgotten to install the hotplug files, as explained in the INSTALLATION section above. Don’t forget to restart hotplug so that it applies these changes.
Unattended shutdowns
The hardware which was used for development of this driver is almost certainly different from what you have, and not all manufacturers follow the USB HID Power Device Class specifications to the letter. You don’t want to find out that yours has issues here when a power failure hits your server room and you’re not around to manually restart your servers.
If you rely on the UPS to shutdown your systems in case of mains failure and to restart them when the power returns, you must test this. You can do so by running upsmon -c fsd. With the mains present, this should bring your systems down and then cycle the power to restart them again. If you do the same without mains present, it should do the same, but in this case, the outputs shall remain off until mains power is applied again.
UPS cuts power too soon
Note that many Cyber Power Systems (CPS) models tend to divide offdelay
by 60 and round down, so the minimum advisable value is 60 (seconds) to avoid
powering off immediately after NUT sends the shutdown command to the UPS.
UPS does not set battery.charge.low but says OK
Note that many Cyber Power Systems (CPS) models tend to allow only certain
values for battery.charge.low
and anything outside of the set of allowed
values are rounded or ignored.
A shell loop like this can help you map out the allowed values:
for i in `seq 90 -1 0`; do echo "set to $i"; \
upsrw -s battery.charge.low=$i -u * -p * cps-big; \
sleep 1; upsc cps-big battery.charge.low; echo ""; \
done
For example, for CPS PR1000LCDRTXL2U model, the only allowed values are
[60,55,50,45,40,35,30,25,20]
and in some cases, your UPS may effectively
not support a value of 10 for the battery.charge.low
setting.
HISTORY
This driver, formerly called newhidups, replaces the legacy hidups driver, which only supported Linux systems.
AUTHORS
Originally sponsored by MGE UPS SYSTEMS.
Now sponsored by Eaton http://opensource.eaton.com
-