Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from 2E.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.8.1

Report #1 with driver nutdrv_qx (detailed comments available)

This device is known to work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

76

battery.runtime

47039

battery.voltage

27.1

battery.voltage.high

29.2

battery.voltage.low

20

battery.voltage.nominal

24

device.type

ups

driver.debug

0

driver.flag.allow_killpower

0

driver.name

nutdrv_qx

driver.parameter.chargetime

24000

driver.parameter.default.battery.voltage.high

29.2

driver.parameter.default.battery.voltage.low

20

driver.parameter.idleload

10

driver.parameter.override.battery.voltage.nominal

24

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.product

ATCL FOR UPS

driver.parameter.productid

0000

driver.parameter.runtimecal

8640,100,17280,50

driver.parameter.serial

ATCL FOR UPS

driver.parameter.synchronous

auto

driver.parameter.vendor

ATCL FOR UPS

driver.parameter.vendorid

0001

driver.state

quiet

driver.version

2.8.2

driver.version.data

Megatec 0.07

driver.version.internal

0.36

driver.version.usb

libusb-1.0.27 (API: 0x100010a)

input.current.nominal

3.6

input.frequency

49.9

input.frequency.nominal

50

input.voltage

223.0

input.voltage.fault

0.0

input.voltage.nominal

220

output.voltage

224.0

ups.beeper.status

disabled

ups.delay.shutdown

30

ups.delay.start

180

ups.firmware

V4.00

ups.load

14

ups.productid

0000

ups.status

OL

ups.temperature

26.0

ups.type

offline / line interactive

ups.vendorid

0001

About this device

It has RJ45 and USB ports, comes with UPSmart utility. Screenshots and logs from the stock utility are included in the nut-ddl ticket.

Device dump generated by ./nut-ddl-dump.sh on Sat, 08 Jun 2024 20:34:25 +0300

Reported at:

Vendor/Manufacturer information:

Further system data or configuration examples:

Driver configuration
[2e-ps1000l]
  driver = "nutdrv_qx"
  port = "auto"
  vendorid = "0001"
  productid = "0000"
  # Certain overrides were needed:
  # LiFePO4 2x 12V
  override.battery.voltage.nominal="24"
  default.battery.voltage.low = "20"
  default.battery.voltage.high = "29.2"
  # 2 hours 24 minutes at 100% load (800W)
  # 4 hours 48 minutes at 50% load (400W)
  runtimecal="8640,100,17280,50"
  # 6.5 hours charge time
  chargetime="24000"
  idleload="10"
Variables per upsrw 2e-ps1000l@localhost listing
# TODO: Convert to RW:... and RO:... markup
:; upsrw 2e-ps1000l@localhost
[driver.debug]
Current debug verbosity level of the driver program
Type: NUMBER
Value: 0

[driver.flag.allow_killpower]
Safety flip-switch to allow the driver daemon to send UPS shutdown command (accessible via driver.killpower)
Type: NUMBER
Value: 0

[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: RANGE NUMBER
Option: "12-600" SELECTED

[ups.delay.start]
Interval to wait before (re)starting the load (seconds)
Type: RANGE NUMBER
Option: "0-599940" SELECTED
Commands per upscmd -l 2e-ps1000l@localhost listing
# TODO: Convert to CMD:... markup
:; upscmd -l 2e-ps1000l@localhost
Instant commands supported on UPS [2e-ps1000l]:

beeper.toggle - Toggle the UPS beeper
driver.killpower - Tell the driver daemon to initiate UPS shutdown; should be unlocked with driver.flag.allow_killpower option or variable setting
driver.reload - Reload running driver configuration from the file system (only works for changes in some options)
driver.reload-or-error - Reload running driver configuration from the file system (only works for changes in some options); return an error if something changed and could not be applied live (so the caller can restart it with new options)
driver.reload-or-exit - Reload running driver configuration from the file system (only works for changes in some options); exit the running driver if something changed and could not be applied live (so service management framework can restart it with new options)
load.off - Turn off the load immediately
load.on - Turn on the load immediately
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress
test.battery.start - Start a battery test
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test

Report #2 with driver nutdrv_qx (detailed comments available)

This device is known to work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

79

battery.runtime

48969

battery.voltage

27.3

battery.voltage.high

29.2

battery.voltage.low

20

battery.voltage.nominal

24

device.type

ups

driver.debug

0

driver.flag.allow_killpower

0

driver.name

nutdrv_qx

driver.parameter.chargetime

24000

driver.parameter.default.battery.voltage.high

29.2

driver.parameter.default.battery.voltage.low

20

driver.parameter.idleload

10

driver.parameter.override.battery.voltage.nominal

24

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.product

ATCL FOR UPS

driver.parameter.productid

0000

driver.parameter.runtimecal

8640,100,17280,50

driver.parameter.serial

ATCL FOR UPS

driver.parameter.synchronous

auto

driver.parameter.vendor

ATCL FOR UPS

driver.parameter.vendorid

0001

driver.state

quiet

driver.version

2.8.2

driver.version.data

Megatec 0.07

driver.version.internal

0.36

driver.version.usb

libusb-1.0.27 (API: 0x100010a)

input.current.nominal

3.6

input.frequency

50.0

input.frequency.nominal

50

input.voltage

221.0

input.voltage.fault

0.0

input.voltage.nominal

220

output.voltage

221.0

ups.beeper.status

disabled

ups.delay.shutdown

30

ups.delay.start

180

ups.firmware

V4.00

ups.load

14

ups.productid

0000

ups.status

OL

ups.temperature

26.0

ups.type

offline / line interactive

ups.vendorid

0001

About this device

It has RJ45 and USB ports, comes with UPSmart utility. Screenshots and logs from the stock utility are included in the nut-ddl ticket.

This device dump was copied from upsc manually in the ticket.

Reported at:

Vendor/Manufacturer information: