Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from APC.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.6.5

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.date

not set

battery.mfr.date

2005/09/16

battery.runtime

1777

battery.runtime.low

120

battery.type

PbAc

battery.voltage

13.5

battery.voltage.nominal

12.0

device.mfr

APC

device.model

Back-UPS ES 725

device.serial

3B0538X11281

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.6.5-3691:3709M

driver.version.data

APC HID 0.95

driver.version.internal

0.37

input.sensitivity

high

input.transfer.high

138

input.transfer.low

88

input.voltage

120.0

input.voltage.nominal

120

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.firmware

802.n2.D

ups.firmware.aux

n2

ups.load

22

ups.mfr

APC

ups.mfr.date

2005/09/16

ups.model

Back-UPS ES 725

ups.productid

0002

ups.serial

3B0538X11281

ups.status

OL

ups.timer.reboot

0

ups.timer.shutdown

-1

ups.vendorid

051d

Report #2 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.date

not set

battery.mfr.date

2005/09/16

battery.runtime

1777

battery.runtime.low

120

battery.type

PbAc

battery.voltage

13.5

battery.voltage.nominal

12.0

device.mfr

APC

device.model

Back-UPS ES 725

device.serial

3B0538X11281

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.6.5-3713:3714M

driver.version.data

APC HID 0.95

driver.version.internal

0.37

input.sensitivity

high

input.transfer.high

138

input.transfer.low

88

input.voltage

120.0

input.voltage.nominal

120

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.firmware

802.n2.D

ups.firmware.aux

n2

ups.load

22

ups.mfr

APC

ups.mfr.date

2005/09/16

ups.model

Back-UPS ES 725

ups.productid

0002

ups.serial

3B0538X11281

ups.status

OL

ups.timer.reboot

0

ups.timer.shutdown

-1

ups.vendorid

051d