Report #1 with driver usbhid-ups (detailed comments available)
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Some more detailed comments are available after the "Known supported…" sections.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.charge
|
|
battery.charge.low
|
|
battery.charge.warning
|
|
battery.date
|
|
battery.mfr.date
|
|
battery.runtime
|
|
battery.runtime.low
|
|
battery.type
|
|
battery.voltage
|
|
battery.voltage.nominal
|
|
device.mfr
|
|
device.model
|
|
device.serial
|
|
device.type
|
|
driver.name
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.parameter.synchronous
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
driver.version.usb
|
|
input.sensitivity
|
|
input.transfer.high
|
|
input.transfer.low
|
|
input.voltage
|
|
input.voltage.nominal
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.firmware
|
|
ups.firmware.aux
|
|
ups.load
|
|
ups.mfr
|
|
ups.mfr.date
|
|
ups.model
|
|
ups.productid
|
|
ups.realpower.nominal
|
|
ups.serial
|
|
ups.status
|
|
ups.test.result
|
|
ups.timer.reboot
|
|
ups.timer.shutdown
|
|
ups.vendorid
|
|
About this device
Device dump generated by ./nut-ddl-dump.sh on Sat, 16 Mar 2024 15:42:38 +0100
Reported at:
Further system data or configuration examples:
upsrw ups@localhost
listing# TODO: Convert to RW:... and RO:... markup
:; upsrw ups@localhost
[battery.charge.low]
Remaining battery level when UPS switches to LB (percent)
Type: STRING
Maximum length: 10
Value: 10
[battery.mfr.date]
Battery manufacturing date
Type: STRING
Maximum length: 10
Value: 2022/12/13
[battery.runtime.low]
Remaining battery runtime when UPS switches to LB (seconds)
Type: STRING
Maximum length: 10
Value: 120
[input.sensitivity]
Input power sensitivity
Type: STRING
Maximum length: 10
Value: medium
[input.transfer.high]
High voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 266
[input.transfer.low]
Low voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 180
[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 10
Value: 20
upscmd -l ups@localhost
listing# TODO: Convert to CMD:... markup
:; upscmd -l ups@localhost
Instant commands supported on UPS [ups]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
shutdown.reboot - Shut down the load briefly while rebooting the UPS
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test
test.panel.start - Start testing the UPS panel
test.panel.stop - Stop a UPS panel test