Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from APC.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.4.1

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

56

battery.charge.low

10

battery.charge.warning

50

battery.runtime

2100

battery.runtime.low

120

battery.type

PbAc

battery.voltage

25.9

battery.voltage.nominal

24.0

device.mfr

American Power Conversion

device.model

Smart-UPS 2200 BI

device.serial

6369960019

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.synchronous

no

driver.version

2.7.4

driver.version.data

APC HID 0.96

driver.version.internal

0.41

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.firmware

UPS 11.0 / ID=1007

ups.mfr

American Power Conversion

ups.mfr.date

2018/04/24

ups.model

Smart-UPS 2200 BI

ups.productid

0003

ups.serial

6369960019

ups.status

OL CHRG

ups.timer.reboot

-1

ups.timer.shutdown

-1

ups.vendorid

051d

About this device

This is a new 2017 model targeted to brazilian market. It does have a USB port and a RJ50 serial port which may need a 940-0625A (RJ50 to DB9) cable.

USB pass-through into a VM works.

Some important readings are missing: I was hoping to see something like input.voltage or ups.load

Missing values are likely due to NUT’s lack of APC-Modbus support: https://github.com/networkupstools/nut/issues/139

Reported at:

Further system data or configuration example:

Commands per upscmd -l worldbyte@localhost listing
# TODO: Convert to CMD:... markup
:; upscmd -l worldbyte@localhost
Instant commands supported on UPS [worldbyte]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
shutdown.reboot - Shut down the load briefly while rebooting the UPS
shutdown.stop - Stop a shutdown in progress