Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.runtime

17820

battery.runtime.low

120

battery.type

PbAc

battery.voltage

27.3

battery.voltage.nominal

24.0

device.mfr

American Power Conversion

device.model

Smart-UPS C 1500

device.serial

3S1632X07908

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.synchronous

no

driver.version

2.7.4-177-g7427a32

driver.version.data

APC HID 0.96

driver.version.internal

0.42

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.firmware

UPS 10.0 / ID=1005

ups.mfr

American Power Conversion

ups.mfr.date

2016/08/17

ups.model

Smart-UPS C 1500

ups.productid

0003

ups.serial

3S1632X07908

ups.status

OL

ups.timer.reboot

-1

ups.timer.shutdown

-1

ups.vendorid

051d

About this device

Reported at:

2.6.4

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

This variable can be set through upsrw to a string value upto the length of 10 characters.

battery.charge.warning

50

battery.runtime

3780

battery.runtime.low

120

This variable can be set through upsrw to a string value upto the length of 120 characters.

battery.type

PbAc

battery.voltage

27.0

battery.voltage.nominal

24.0

device.mfr

American Power Conversion

device.model

Smart-UPS C 1500

device.serial

3S1437X00405

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.productid

0003

driver.parameter.vendorid

051d

driver.version

2.6.4

driver.version.data

APC HID 0.95

driver.version.internal

0.37

ups.beeper.status

disabled

ups.delay.shutdown

20

This variable can be set through upsrw to a string value upto the length of 20 characters.

ups.firmware

UPS 09.6 / ID=1005

ups.mfr

American Power Conversion

ups.mfr.date

2014/09/09

ups.model

Smart-UPS C 1500

ups.productid

0003

ups.serial

3S1437X00405

ups.status

OL

ups.timer.reboot

-1

ups.timer.shutdown

-1

ups.vendorid

051d

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.mute

  • beeper.off

  • beeper.on

  • load.off

  • load.off.delay

  • shutdown.reboot

  • shutdown.stop