Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.6.3

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

20

battery.mfr.date

CPS

battery.runtime

2790

battery.runtime.low

300

battery.type

PbAcid

battery.voltage

16.0

Might not have battery voltage sensor.

battery.voltage.nominal

24

device.mfr

CP1000PFCLCD

device.model

CRDA103*AF1

device.serial

CPS

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.6.3

driver.version.data

CyberPower HID 0.3

driver.version.internal

0.35

input.transfer.high

139

input.transfer.low

88

input.voltage

119.0

input.voltage.nominal

120

output.voltage

136.0

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.load

12

ups.mfr

CP1000PFCLCD

ups.model

CRDA103*AF1

ups.productid

0501

ups.realpower.nominal

600

ups.serial

CPS

ups.status

OL

ups.test.result

No test initiated

ups.timer.shutdown

-60

ups.timer.start

-60

ups.vendorid

0764

2.6.0

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

20

battery.mfr.date

CPS

battery.runtime

2220

battery.runtime.low

300

battery.type

PbAcid

battery.voltage

16.0

might not have battery voltage sensor.

battery.voltage.nominal

24

device.mfr

CP1000PFCLCD

device.model

CRDA103-461

device.serial

CPS

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.6.0

driver.version.data

CyberPower HID 0.3

driver.version.internal

0.35

input.transfer.high

139

input.transfer.low

88

input.voltage

121.0

input.voltage.nominal

120

output.voltage

137.0

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.load

16

ups.mfr

CP1000PFCLCD

ups.model

CRDA103-461

ups.productid

0501

ups.realpower.nominal

600

ups.serial

CPS

ups.status

OL

ups.test.result

No test initiated

ups.timer.shutdown

-60

ups.timer.start

-60

ups.vendorid

0764