Click here to see reports of other supported models from Cyber Power Systems.
When a user reports that a variable/command is not right then it will be highlighted by a red underline. Bad values/ranges/etc… will get a red dashed outline or red solid left border. The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left. |
2.7.4
Report #1 with driver usbhid-ups (detailed comments available)
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Some more detailed comments are available after the "Known supported…" sections.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.charge
|
|
battery.charge.low
|
|
battery.charge.warning
|
|
battery.mfr.date
|
|
battery.runtime
|
|
battery.runtime.low
|
|
battery.type
|
|
battery.voltage
|
|
battery.voltage.nominal
|
|
device.mfr
|
|
device.model
|
|
device.serial
|
|
device.type
|
|
driver.name
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.parameter.synchronous
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.transfer.high
|
|
input.transfer.low
|
|
input.voltage
|
|
input.voltage.nominal
|
|
output.voltage
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.delay.start
|
|
ups.load
|
|
ups.mfr
|
|
ups.model
|
|
ups.productid
|
|
ups.realpower.nominal
|
|
ups.serial
|
|
ups.status
|
|
ups.test.result
|
|
ups.timer.shutdown
|
|
ups.timer.start
|
|
ups.vendorid
|
|
About this device
Reported at:
Further system data or configuration examples:
upsrw CP1500PFCLCD@localhost
listing# TODO: Convert to RW:... and RO:... markup
:; upsrw CP1500PFCLCD@localhost
[battery.charge.low]
Remaining battery level when UPS switches to LB (percent)
Type: STRING
Maximum length: 10
Value: 10
[battery.runtime.low]
Remaining battery runtime when UPS switches to LB (seconds)
Type: STRING
Maximum length: 10
Value: 300
[input.transfer.high]
High voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 139
[input.transfer.low]
Low voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 88
[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 10
Value: 20
[ups.delay.start]
Interval to wait before (re)starting the load (seconds)
Type: STRING
Maximum length: 10
Value: 30
upscmd -l CP1500PFCLCD@localhost
listing# TODO: Convert to CMD:... markup
:; upscmd -l CP1500PFCLCD@localhost
Instant commands supported on UPS [CP1500PFCLCD]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
load.on - Turn on the load immediately
load.on.delay - Turn on the load with a delay (seconds)
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test
Report #2 with driver usbhid-ups (detailed comments available)
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Some more detailed comments are available after the "Known supported…" sections.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.charge
|
|
battery.charge.low
|
|
battery.charge.warning
|
|
battery.mfr.date
|
|
battery.runtime
|
|
battery.runtime.low
|
|
battery.type
|
|
battery.voltage
|
|
battery.voltage.nominal
|
|
device.mfr
|
|
device.model
|
|
device.serial
|
|
device.type
|
|
driver.name
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.parameter.synchronous
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.transfer.high
|
|
input.transfer.low
|
|
input.voltage
|
|
input.voltage.nominal
|
|
output.voltage
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.delay.start
|
|
ups.load
|
|
ups.mfr
|
|
ups.model
|
|
ups.productid
|
|
ups.realpower.nominal
|
|
ups.serial
|
|
ups.status
|
|
ups.test.result
|
|
ups.timer.shutdown
|
|
ups.timer.start
|
|
ups.vendorid
|
|
About this device
I’m not able to set battery.charge.low
:
:; upsrw -s battery.charge.low=20 -u * -p * CyberPower
OK
:; upsc CyberPower battery.charge.low
10
:; upsrw -s battery.charge.low=5 -u upsuser -p mypwd CyberpowerUPS
OK
:; upsc CyberpowerUPS battery.charge.low
10
device might internally only handle certain discrete values for that. |
Reported at:
2.7.1
Report #1 with driver usbhid-ups (detailed comments available)
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Some more detailed comments are available after the "Known supported…" sections.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.charge
|
|
battery.charge.low
|
|
battery.charge.warning
|
|
battery.mfr.date
|
|
battery.runtime
|
|
battery.runtime.low
|
|
battery.type
|
|
battery.voltage
|
The value should be around CyberPower states that battery voltage is not supported in this model of UPS. It’s not even shown in their PowerPanel software. |
battery.voltage.nominal
|
|
device.mfr
|
|
device.model
|
|
device.serial
|
|
device.type
|
|
driver.name
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.parameter.vendorid
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.transfer.high
|
|
input.transfer.low
|
|
input.voltage
|
|
input.voltage.nominal
|
|
output.voltage
|
Always at |
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.delay.start
|
|
ups.load
|
|
ups.mfr
|
|
ups.model
|
|
ups.productid
|
|
ups.realpower.nominal
|
|
ups.serial
|
|
ups.status
|
|
ups.test.result
|
|
ups.timer.shutdown
|
|
ups.timer.start
|
|
ups.vendorid
|
|