2.4.3

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge.low

10

battery.charge.warning

20

battery.mfr.date

CPS

battery.runtime

960

battery.runtime.low

300

battery.type

PbAcid

battery.voltage

4.9

battery.voltage.nominal

12

device.mfr

CPS

device.model

CP550HG

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.4.3

driver.version.data

CyberPower HID 0.3

driver.version.internal

0.34

input.transfer.high

0

input.transfer.low

0

input.voltage

121.0

input.voltage.nominal

120

output.voltage

120.0

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.load

46

ups.mfr

CPS

ups.model

CP550HG

ups.productid

0501

ups.realpower.nominal

330

ups.status

OL

ups.test.result

No test initiated

ups.timer.shutdown

-60

ups.timer.start

0

ups.vendorid

0764