Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Cyber Power Systems.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.4

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

This variable can be set through upsrw to a string value upto the length of 10 characters.

battery.charge.warning

20

battery.mfr.date

CPS

battery.runtime

2475

battery.runtime.low

300

This variable can be set through upsrw to a string value upto the length of 10 characters.

battery.type

PbAcid

battery.voltage

14.2

battery.voltage.nominal

12

device.mfr

CPS

device.model

EC750G

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.synchronous

no

driver.version

2.7.4

driver.version.data

CyberPower HID 0.4

driver.version.internal

0.41

input.transfer.high

140

This variable can be set through upsrw to a string value upto the length of 10 characters.

input.transfer.low

96

This variable can be set through upsrw to a string value upto the length of 10 characters.

input.voltage

120.0

input.voltage.nominal

120

output.voltage

120.0

ups.beeper.status

enabled

ups.delay.shutdown

20

This variable can be set through upsrw to a string value upto the length of 10 characters.

times are in seconds, but are internally rounded down to minutes by the UPS.

ups.delay.start

30

This variable can be set through upsrw to a string value upto the length of 10 characters.

ups.load

18

ups.mfr

CPS

ups.model

EC750G

ups.productid

0501

ups.realpower.nominal

450

ups.status

OL

ups.test.result

No test initiated

ups.timer.shutdown

-60

ups.timer.start

0

ups.vendorid

0764

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.mute

  • beeper.off

  • beeper.on

  • load.off

  • load.off.delay

  • load.on

  • load.on.delay

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop