Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Cyber Power Systems.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.4

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

99

battery.charge.low

10

battery.charge.warning

20

battery.mfr.date

CPS

battery.runtime

2494

battery.runtime.low

300

battery.type

PbAcid

battery.voltage

13.6

battery.voltage.nominal

12

device.mfr

CPS

device.model

LE850G

device.serial

QBNMT7001080

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.synchronous

no

driver.version

2.7.4

driver.version.data

CyberPower HID 0.4

driver.version.internal

0.41

input.voltage

118.0

input.voltage.nominal

120

output.voltage

142.0

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.load

13

ups.mfr

CPS

ups.model

LE850G

ups.productid

0501

ups.realpower.nominal

460

ups.serial

QBNMT7001080

ups.status

OL

ups.test.result

No test initiated

ups.timer.shutdown

-60

ups.timer.start

-60

ups.vendorid

0764

About this device

Device dump generated by ./nut-ddl-dump.sh on Sun, 11 Dec 2022 12:12:57 -0500

Further system data or configuration examples:

Variables per upsrw ups@localhost listing
# TODO: Convert to RW:... and RO:... markup
:; upsrw ups@localhost
[battery.charge.low]
Description unavailable
Type: STRING
Maximum length: 10
Value: 10

[battery.runtime.low]
Description unavailable
Type: STRING
Maximum length: 10
Value: 300

[ups.delay.shutdown]
Description unavailable
Type: STRING
Maximum length: 10
Value: 20

[ups.delay.start]
Description unavailable
Type: STRING
Maximum length: 10
Value: 30
Commands per upscmd -l ups@localhost listing
# TODO: Convert to CMD:... markup
:; upscmd -l ups@localhost
Instant commands supported on UPS [ups]:

beeper.disable - Description unavailable
beeper.enable - Description unavailable
beeper.mute - Description unavailable
beeper.off - Description unavailable
beeper.on - Description unavailable
load.off - Description unavailable
load.off.delay - Description unavailable
load.on - Description unavailable
load.on.delay - Description unavailable
shutdown.return - Description unavailable
shutdown.stayoff - Description unavailable
shutdown.stop - Description unavailable
test.battery.start.deep - Description unavailable
test.battery.start.quick - Description unavailable
test.battery.stop - Description unavailable