Click here to see reports of other supported models from Cyber Power Systems.
When a user reports that a variable/command is not right then it will be highlighted by a red underline. Bad values/ranges/etc… will get a red dashed outline or red solid left border. The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left. |
2.7.4
Report #1 with driver usbhid-ups (detailed comments available)
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Some more detailed comments are available after the "Known supported…" sections.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.charge
|
|
battery.charge.low
|
|
battery.charge.warning
|
|
battery.mfr.date
|
|
battery.runtime
|
|
battery.runtime.low
|
|
battery.type
|
|
battery.voltage
|
|
battery.voltage.nominal
|
|
device.mfr
|
|
device.model
|
|
device.type
|
|
driver.name
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.parameter.synchronous
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.transfer.high
|
|
input.transfer.low
|
|
input.voltage
|
|
input.voltage.nominal
|
|
output.voltage
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.delay.start
|
|
ups.load
|
|
ups.mfr
|
|
ups.model
|
|
ups.productid
|
|
ups.realpower.nominal
|
|
ups.status
|
|
ups.test.result
|
|
ups.timer.shutdown
|
|
ups.timer.start
|
|
ups.vendorid
|
|
About this device
passed test.battery.start.quick
poweroff
and poweron
can add later
Reported at:
Vendor/Manufacturer information:
Further system data or configuration examples:
lsusb
listing:; lsusb -v -s 007:002
Bus 007 Device 002: ID 0764:0501 Cyber Power System, Inc. CP1500 AVR UPS
Device Descriptor:
bLength 18
bDescriptorType 1
bcdUSB 1.10
bDeviceClass 0
bDeviceSubClass 0
bDeviceProtocol 0
bMaxPacketSize0 8
idVendor 0x0764 Cyber Power System, Inc.
idProduct 0x0501 CP1500 AVR UPS
bcdDevice 0.01
iManufacturer 3 CPS
iProduct 1 UT2200E
iSerial 0
bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 0x0022
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 0
bmAttributes 0x80
(Bus Powered)
MaxPower 50mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Device
bInterfaceSubClass 0
bInterfaceProtocol 0
iInterface 0
HID Device Descriptor:
bLength 9
bDescriptorType 33
bcdHID 1.10
bCountryCode 33 US
bNumDescriptors 1
bDescriptorType 34 Report
wDescriptorLength 562
Report Descriptors:
** UNAVAILABLE **
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x81 EP 1 IN
bmAttributes 3
Transfer Type Interrupt
Synch Type None
Usage Type Data
wMaxPacketSize 0x0008 1x 8 bytes
bInterval 10
upsrw cps1500avr@localhost
listing# TODO: Convert to RW:... and RO:... markup
:; upsrw cps1500avr@localhost
[battery.charge.low]
Remaining battery level when UPS switches to LB (percent)
Type: STRING
Maximum length: 10
Value: 10
[battery.runtime.low]
Remaining battery runtime when UPS switches to LB (seconds)
Type: STRING
Maximum length: 10
Value: 300
[input.transfer.high]
High voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 0
[input.transfer.low]
Low voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 0
[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 10
Value: 20
[ups.delay.start]
Interval to wait before (re)starting the load (seconds)
Type: STRING
Maximum length: 10
Value: 30
upscmd -l cps1500avr@localhost
listing# TODO: Convert to CMD:... markup
:; upscmd -l cps1500avr@localhost
Instant commands supported on UPS [cps1500avr]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
load.on - Turn on the load immediately
load.on.delay - Turn on the load with a delay (seconds)
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test