Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.capacity

100

battery.charge

100.0

battery.charge.low

20

battery.charge.warning

20

battery.runtime

4988

battery.temperature

24.9

battery.voltage

81.9

battery.voltage.nominal

72

device.mfr

DELTA

device.model

UPS302R2000B0BA

device.serial

[reduced]

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

5

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.synchronous

no

driver.version

2.7.4-1-gb34f2434

driver.version.data

Delta UPS HID 0.1

driver.version.internal

0.41

input.frequency

59.9

input.sensitivity

normal

input.source

normal

input.transfer.high

280

input.transfer.high.max

280

input.transfer.high.min

270

input.transfer.low

80

input.transfer.low.max

90

input.transfer.low.min

80

input.voltage

228.0

output.current

1.2

output.frequency

59.9

output.frequency.nominal

60

output.voltage

221.0

output.voltage.nominal

220

ups.beeper.status

enabled

ups.delay.start

0

ups.load

8.0

ups.mfr

DELTA

ups.model

UPS302R2000B0BA

ups.power.nominal

3000

ups.productid

041b

ups.realpower

242.0

ups.serial

[reduced]

ups.start.auto

yes

ups.status

OL

ups.timer.reboot

0

ups.timer.shutdown

-1

ups.timer.start

0

ups.type

online

ups.vendorid

05dd

About this device

Delta UPS Amplon R Series

Device dump generated by ./tools/nut-ddl-dump.sh on Wed, 21 Apr 2021 01:02:14 +0900

Reported at:

Vendor/Manufacturer information:

Further system data or configuration examples:

Variables per upsrw delta@localhost listing
# TODO: Convert to RW:... and RO:... markup
:; upsrw delta@localhost
[battery.charge.low]
Remaining battery level when UPS switches to LB (percent)
Type: STRING
Maximum length: 5
Value: 20

[input.sensitivity]
Input power sensitivity
Type: NUMBER

[input.transfer.high]
High voltage transfer point (V)
Type: NUMBER

[input.transfer.low]
Low voltage transfer point (V)
Type: NUMBER

[ups.delay.start]
Interval to wait before (re)starting the load (seconds)
Type: NUMBER

[ups.start.auto]
UPS starts when mains is (re)applied
Type: NUMBER
Commands per upscmd -l delta@localhost listing
# TODO: Convert to CMD:... markup
:; upscmd -l delta@localhost
Instant commands supported on UPS [delta]:

beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
load.on - Turn on the load immediately
load.on.delay - Turn on the load with a delay (seconds)
shutdown.reboot - Shut down the load briefly while rebooting the UPS
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test

Report #2 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.capacity

100

battery.charge

100.0

battery.charge.low

20

battery.charge.warning

20

battery.runtime

6496

battery.temperature

31.9

battery.voltage

54.1

battery.voltage.nominal

48

device.mfr

DELTA

device.model

UPS202R2000B0BA

device.serial

[reduced]

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

5

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.synchronous

no

driver.version

2.7.4-1-gb34f2434

driver.version.data

Delta UPS HID 0.1

driver.version.internal

0.41

input.frequency

59.9

input.sensitivity

normal

input.source

normal

input.transfer.high

280

input.transfer.high.max

280

input.transfer.high.min

270

input.transfer.low

80

input.transfer.low.max

90

input.transfer.low.min

80

input.voltage

218.0

output.current

0.0

output.frequency

59.9

output.frequency.nominal

60

output.voltage

218.0

output.voltage.nominal

220

ups.beeper.status

enabled

ups.delay.start

0

ups.load

8.0

ups.mfr

DELTA

ups.model

UPS202R2000B0BA

ups.power.nominal

2000

ups.productid

041b

ups.realpower

155.0

ups.serial

[reduced]

ups.start.auto

yes

ups.status

OL

ups.timer.reboot

0

ups.timer.shutdown

-1

ups.timer.start

0

ups.type

online

ups.vendorid

05dd

About this device

Delta UPS Amplon R Series, new Delta HID subdriver - tested on R1K and R3K model.

Reported at:

Vendor/Manufacturer information: