Click here to see reports of other supported models from Eaton.
When a user reports that a variable/command is not right then it will be highlighted by a red underline. Bad values/ranges/etc… will get a red dashed outline or red solid left border. The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left. |
2.7.4
Report #1 with driver usbhid-ups (detailed comments available)
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Some more detailed comments are available after the "Known supported…" sections.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.capacity
|
|
battery.charge
|
|
battery.charge.low
|
|
battery.charge.restart
|
|
battery.charger.status
|
|
battery.energysave
|
|
battery.energysave.delay
|
|
battery.energysave.load
|
|
battery.protection
|
|
battery.runtime
|
|
battery.type
|
|
device.mfr
|
|
device.model
|
|
device.serial
|
|
device.type
|
|
driver.name
|
|
driver.parameter.bus
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.parameter.product
|
|
driver.parameter.productid
|
|
driver.parameter.serial
|
|
driver.parameter.synchronous
|
|
driver.parameter.vendor
|
|
driver.parameter.vendorid
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.current
|
|
input.frequency
|
|
input.frequency.nominal
|
|
input.sensitivity
|
|
input.transfer.boost.low
|
|
input.transfer.high
|
|
input.transfer.low
|
|
input.transfer.trim.high
|
|
input.voltage
|
|
input.voltage.nominal
|
|
outlet.1.status
|
|
outlet.desc
|
|
outlet.id
|
|
outlet.switchable
|
|
output.current
|
|
output.frequency
|
|
output.frequency.nominal
|
|
output.powerfactor
|
|
output.voltage
|
|
output.voltage.nominal
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.delay.start
|
|
ups.efficiency
|
|
ups.firmware
|
|
ups.load
|
|
ups.load.high
|
|
ups.mfr
|
|
ups.model
|
|
ups.power
|
|
ups.power.nominal
|
|
ups.productid
|
|
ups.realpower
|
|
ups.realpower.nominal
|
|
ups.serial
|
|
ups.shutdown
|
|
ups.start.auto
|
|
ups.start.battery
|
|
ups.start.reboot
|
|
ups.status
|
|
ups.test.interval
|
|
ups.test.result
|
|
ups.timer.shutdown
|
|
ups.timer.start
|
|
ups.type
|
|
ups.vendorid
|
|
About this device
Device dump generated by ./nut-ddl-dump.sh on Tue, 29 Nov 2022 16:53:45 +0100
Further system data or configuration examples:
upsrw eaton@localhost
listing# TODO: Convert to RW:... and RO:... markup
:; upsrw eaton@localhost
[battery.charge.low]
Remaining battery level when UPS switches to LB (percent)
Type: STRING
Maximum length: 5
Value: 20
[battery.charge.restart]
Minimum battery level for restart after power off (percent)
Type: STRING
Maximum length: 3
Value: 0
[battery.energysave]
Switch off when running on battery and no/low load
Type: STRING
Maximum length: 5
Value: no
[battery.energysave.delay]
Delay before switch off UPS if on battery and load level low (min)
Type: STRING
Maximum length: 5
Value: 300
[battery.energysave.load]
Switch off UPS if on battery and load level lower (percent)
Type: STRING
Maximum length: 5
Value: 5
[battery.protection]
Prevent deep discharge of battery
Type: STRING
Maximum length: 5
Value: yes
[input.sensitivity]
Input power sensitivity
Type: STRING
Maximum length: 10
Value: normal
[input.transfer.boost.low]
Low voltage boosting transfer point (V)
Type: STRING
Maximum length: 5
Value: 207
[input.transfer.high]
High voltage transfer point (V)
Type: STRING
Maximum length: 5
Value: 276
[input.transfer.low]
Low voltage transfer point (V)
Type: STRING
Maximum length: 5
Value: 184
[input.transfer.trim.high]
High voltage trimming transfer point (V)
Type: STRING
Maximum length: 5
Value: 243
[outlet.desc]
Outlet description
Type: STRING
Maximum length: 20
Value: Main Outlet
[output.voltage.nominal]
Nominal output voltage (V)
Type: ENUM
Option: "200"
Option: "208"
Option: "220"
Option: "230" SELECTED
Option: "240"
[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 10
Value: 20
[ups.delay.start]
Interval to wait before (re)starting the load (seconds)
Type: STRING
Maximum length: 10
Value: 30
[ups.load.high]
Load when UPS switches to overload condition (percent)
Type: STRING
Maximum length: 5
Value: 105
[ups.shutdown]
Description unavailable
Type: ENUM
Option: "disabled"
Option: "enabled" SELECTED
[ups.start.auto]
UPS starts when mains is (re)applied
Type: STRING
Maximum length: 5
Value: yes
[ups.start.battery]
Allow to start UPS from battery
Type: STRING
Maximum length: 5
Value: yes
[ups.start.reboot]
UPS reboots when power returns during shutdown delay
Type: STRING
Maximum length: 5
Value: yes
[ups.test.interval]
Interval between self tests (seconds)
Type: STRING
Maximum length: 8
Value: 2592000
upscmd -l eaton@localhost
listing# TODO: Convert to CMD:... markup
:; upscmd -l eaton@localhost
Instant commands supported on UPS [eaton]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
load.on - Turn on the load immediately
load.on.delay - Turn on the load with a delay (seconds)
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test