Click here to see reports of other supported models from Energy Technologies.
When a user reports that a variable/command is not right then it will be highlighted by a red underline. Bad values/ranges/etc… will get a red dashed outline or red solid left border. The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left. |
2.7.4
Report #1 with driver blazer_ser (detailed comments available)
This device is known to work with driver blazer_ser. It may also work with driver nutdrv_qx.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Some more detailed comments are available after the "Known supported…" sections.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.charge
|
|
battery.voltage
|
|
battery.voltage.high
|
|
battery.voltage.low
|
|
battery.voltage.nominal
|
|
device.mfr
|
|
device.model
|
|
device.type
|
|
driver.name
|
|
driver.parameter.offdelay
|
|
driver.parameter.ondelay
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.parameter.synchronous
|
|
driver.version
|
|
driver.version.internal
|
|
input.current.nominal
|
|
input.frequency
|
|
input.frequency.nominal
|
|
input.voltage
|
|
input.voltage.fault
|
|
input.voltage.nominal
|
|
output.voltage
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.delay.start
|
|
ups.firmware
|
|
ups.load
|
|
ups.mfr
|
|
ups.model
|
|
ups.status
|
|
ups.temperature
|
|
ups.type
|
|
About this device
EnergTechnology DPK1/1-3 aka Energy Technologies DPK1/1-3
Shutdown sequence works, including shutdown of the UPS itself, and automatically powering up after AC back.
upsrw
gives no output.
Reported at:
Vendor/Manufacturer information:
Further system data or configuration examples:
[dpk]
driver = blazer_ser
port = /dev/ttyS0
desc = "DPK-1/1-3"
offdelay = 60
ondelay = 1
:; upsdrvctl start
Network UPS Tools - UPS driver controller 2.7.4
Network UPS Tools - Megatec/Q1 protocol serial driver 1.57 (2.7.4)
Supported UPS detected with megatec protocol
Vendor information read in 1 tries
No values provided for battery high/low voltages in ups.conf
Using 'guestimation' (low: 83.200000, high: 104.000000)!
Battery runtime will not be calculated (runtimecal not set)
upscmd -l dpk@localhost
listing# TODO: Convert to CMD:... markup
:; upscmd -l dpk@localhost
Instant commands supported on UPS [dpk]:
beeper.toggle - Toggle the UPS beeper
load.off - Turn off the load immediately
load.on - Turn on the load immediately
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress
test.battery.start - Start a battery test
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test