2.6.3

Report #1 with driver usbhid-ups

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.capacity

5.00

battery.charge

98

battery.runtime

14206

battery.runtime.low

180

battery.type

PbAc

device.mfr

HP

device.model

HP R/T3000 UPS LI RT3000

device.serial

3C80481546

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.6.3-3524M

driver.version.data

MGE HID 1.30

driver.version.internal

0.36

input.bypass.current

0.00

input.bypass.voltage

242.0

input.current

1.50

input.frequency

50.0

input.frequency.nominal

50

input.transfer.high

288

input.transfer.low

160

input.voltage

242.0

input.voltage.nominal

230

outlet.1.delay.start

0

outlet.1.desc

PowerShare Outlet 1

outlet.1.id

1

outlet.1.status

on

outlet.1.switchable

yes

outlet.2.delay.start

1

outlet.2.desc

PowerShare Outlet 2

outlet.2.id

2

outlet.2.status

on

outlet.2.switchable

yes

output.current

0.00

output.frequency

49.8

output.frequency.nominal

50

output.voltage

224.0

output.voltage.nominal

230

ups.beeper.status

enabled

ups.date

2012/04/10

ups.delay.shutdown

20

ups.delay.start

30

ups.firmware

00.01.0019;00.01.00

ups.load

0

ups.load.high

112

ups.mfr

HP

ups.model

HP R/T3000 UPS LI RT3000

ups.power

0

ups.power.nominal

3300

ups.productid

1fe5

ups.realpower

0

ups.realpower.nominal

3000

ups.serial

3C80481546

ups.start.auto

yes

ups.start.battery

no

ups.start.reboot

yes

ups.status

OL

ups.temperature

30.9

ups.test.result

No test initiated

ups.time

18:10:56

ups.timer.shutdown

-1

ups.timer.start

-1

ups.type

offline / line interactive

ups.vendorid

03f0