Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from INELT.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.4

Report #1 with driver nutdrv-qx (detailed comments available)

This device is known to work with driver nutdrv-qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

88

battery.energysave

no

This variable can be set through upsrw to one of the following values:

  • no

  • yes

battery.packs

22

This variable can be set through upsrw within the following ranges:

  • 1..99

battery.protection

yes

This variable can be set through upsrw to one of the following values:

  • no

  • yes

battery.runtime

26040

battery.voltage

13.70

battery.voltage.nominal

12.0

device.model

WPHVT1K0L

device.type

ups

driver.name

nutdrv_qx

driver.parameter.pollfreq

60

driver.parameter.pollinterval

5

driver.parameter.port

auto

driver.parameter.productid

5161

driver.parameter.protocol

voltronic

driver.parameter.subdriver

cypress

driver.parameter.synchronous

no

driver.parameter.vendorid

0665

driver.version

2.7.4

driver.version.data

Voltronic 0.06

driver.version.internal

0.28

input.current.nominal

4.0

input.frequency

50.0

input.frequency.high

53.0

This variable can be set through upsrw within the following ranges:

  • 53..60

input.frequency.low

47.0

This variable can be set through upsrw within the following ranges:

  • 40..47

input.frequency.nominal

50.0

input.phases

1

input.transfer.high

242

This variable can be set through upsrw within the following ranges:

  • 237..254

input.transfer.high.max

254

input.transfer.high.min

237

input.transfer.low

218

This variable can be set through upsrw within the following ranges:

  • 206..223

input.transfer.low.max

223

input.transfer.low.min

206

input.voltage

241.9

input.voltage.nominal

230.0

output.current

1.2

output.current.nominal

4

output.frequency

50.0

output.frequency.nominal

50.0

output.phases

1

output.power.maximum.percent

30

output.power.minimum.percent

25

output.powerfactor

0.8

output.voltage

229.8

output.voltage.nominal

230.0

ups.beeper.status

enabled

ups.delay.shutdown

30

This variable can be set through upsrw within the following ranges:

  • 12..5940

ups.delay.start

180

This variable can be set through upsrw within the following ranges:

  • 0..599940

ups.firmware

01690.01

ups.firmware.aux

P01

ups.load

29

ups.power.nominal

1000

ups.productid

5161

ups.start.auto

yes

This variable can be set through upsrw to one of the following values:

  • no

  • yes

ups.start.battery

yes

This variable can be set through upsrw to one of the following values:

  • no

  • yes

ups.status

OL

ups.temperature

24.1

ups.type

online

ups.vendorid

0665

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.toggle

  • bypass.start

  • bypass.stop

  • load.off

  • load.on

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop