2.6.0

Report #1 with driver blazer_ser (detailed comments available)

This device is known to work with driver blazer_ser. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.voltage

54.00

battery.voltage.nominal

48.0

beeper.status

disabled

device.mfr


device.model


device.type

ups

driver.name

blazer_ser

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ttyS0

driver.version

2.6.0

driver.version.internal

1.51

input.current.nominal

0.0

input.frequency

50.0

input.frequency.nominal

50

input.voltage

246.5

input.voltage.fault

140.0

input.voltage.nominal

230

output.voltage

246.5

ups.delay.shutdown

30

ups.delay.start

180

ups.firmware

IN03064B

ups.load

4

ups.mfr


ups.model


ups.status

OL

ups.temperature

25.0

Temperature never changes

ups.type

offline / line interactive