Report #1 with driver mge-shut (detailed comments available)

This device is known to work with driver mge-shut.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

82

battery.charge.low

20

This variable can be set through upsrw to a string value.

battery.runtime

03979

driver.name

mge-shut

driver.parameter.offdelay

120

driver.parameter.ondelay

15

driver.parameter.port

/dev/ttyS1

driver.version

2.0.3

driver.version.internal

0.65

input.frequency

49

input.voltage

229

outlet.0.desc

Main Outlet

This variable can be set through upsrw to a string value.

outlet.0.id

0

outlet.0.switchable

1

outlet.1.autoswitch.charge.low

0

This variable can be set through upsrw to a string value.

outlet.1.delay.shutdown

-1

This variable can be set through upsrw to a string value.

outlet.1.delay.start

-1

This variable can be set through upsrw to a string value.

outlet.1.desc

PowerShare Outlet 1

This variable can be set through upsrw to a string value.

outlet.1.id

1

outlet.1.switch

1

This variable can be set through upsrw to a string value.

outlet.1.switchable

1

outlet.2.autoswitch.charge.low

0

This variable can be set through upsrw to a string value.

outlet.2.delay.shutdown

-1

This variable can be set through upsrw to a string value.

outlet.2.delay.start

-1

This variable can be set through upsrw to a string value.

outlet.2.desc

PowerShare Outlet 2

This variable can be set through upsrw to a string value.

outlet.2.id

2

outlet.2.switch

1

This variable can be set through upsrw to a string value.

outlet.2.switchable

1

output.frequency

49

output.voltage

230

output.voltage.target.battery

40

output.voltage.target.line

40

ups.delay.shutdown

-1

This variable can be set through upsrw to a string value.

ups.delay.start

-1

This variable can be set through upsrw to a string value.

ups.load

10

ups.mfr

MGE UPS SYSTEMS

ups.power.nominal

1000

ups.serial

1Y2G15069

ups.status

OL CHRG

ups.test.result

Done and passed