Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from MGE UPS SYSTEMS.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.6.1

Report #1 with driver mge-shut (detailed comments available)

This device is known to work with driver mge-shut.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

30

battery.runtime

456

device.mfr

MGE UPS SYSTEMS

device.model

ellipse premium 800

device.serial

unknown

device.type

ups

driver.name

mge-shut

driver.parameter.pollinterval

2

driver.parameter.port

/dev/cuau0

driver.version

2.6.1

driver.version.internal

0.69

outlet.1.autoswitch.charge.low

0

This variable can be set through upsrw to a string value.

outlet.1.desc

PowerShare Outlet 1

This variable can be set through upsrw to a string value.

outlet.1.id

2

outlet.1.switch

1

This variable can be set through upsrw to a string value.

outlet.1.switchable

1

outlet.desc

Main Outlet

This variable can be set through upsrw to a string value.

outlet.id

1

outlet.switchable

0

output.voltage

230

ups.load

40

ups.mfr

MGE UPS SYSTEMS

ups.model

ellipse premium 800

ups.power.nominal

800

ups.serial

unknown

ups.status

OL CHRG

ups.timer.shutdown

-1

This variable can be set through upsrw to a string value.

ups.timer.start

-1

This variable can be set through upsrw to a string value.

Known supported commands

This device is known to support the following NUT’s instant commands:

  • load.off

  • load.on

  • shutdown.return

  • shutdown.stayoff

  • test.battery.start

  • test.battery.stop

Report #2 with driver newmge-shut (detailed comments available)

This device is known to work with driver newmge-shut, now replaced by the mge-shut one.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

30

battery.runtime

456

battery.type

PbAc

device.mfr

MGE UPS SYSTEMS

device.model

ellipse premium 800

device.serial

unknown

device.type

ups

driver.name

newmge-shut

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

/dev/cuau0

driver.version

2.6.1

driver.version.data

MGE HID 1.21

driver.version.internal

0.35

input.transfer.high

264

input.transfer.low

161

outlet.1.desc

PowerShare Outlet 1

outlet.1.id

2

outlet.1.status

on

outlet.1.switchable

yes

outlet.desc

Main Outlet

outlet.id

2

outlet.switchable

no

output.frequency.nominal

50

output.voltage

230.0

output.voltage.nominal

161

This variable can be set through upsrw to one of the following values:

  • 200

  • 208

  • 220

  • 230

  • 240

  • 100

  • 110

  • 120

  • 127

ups.delay.shutdown

20

ups.delay.start

30

ups.load

42

ups.mfr

MGE UPS SYSTEMS

ups.model

ellipse premium 800

ups.power.nominal

800

ups.productid

ffff

ups.serial

unknown

ups.status

OL CHRG BOOST

ups.timer.shutdown

-1

ups.timer.start

-10

ups.vendorid

0463