Report #1 with driver snmp-ups (detailed comments available)

This device is known to work with driver snmp-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100.00

battery.runtime

0.00

battery.voltage

339.90

device.mfr

Net Vision 7 v7.40

device.model

U4BC02CB00NY100

device.serial

Pxxxxxxxxx

device.type

ups

driver.name

snmp-ups

driver.parameter.mibs

auto

driver.parameter.pollfreq

60

driver.parameter.pollinterval

2

driver.parameter.port

10.10.10.10

driver.parameter.snmp_version

v1

driver.parameter.synchronous

no

driver.version

2.7.4

driver.version.data

netvision MIB 0.4

driver.version.internal

0.97

input.L1-N.voltage

231.00

input.L1.current

1.60

input.L2-N.voltage

230.00

input.L2.current

1.60

input.L3-N.voltage

231.00

input.L3.current

1.70

input.bypass.L1-N.voltage

236.00

input.bypass.L1.current

0.00

input.bypass.L2-N.voltage

235.00

input.bypass.L2.current

0.00

input.bypass.L3-N.voltage

235.00

input.bypass.L3.current

0.00

input.bypass.frequency

4.90

input.bypass.phases

3.00

input.frequency

49.90

input.phases

3.00

output.L1-N.voltage

230.00

output.L1.current

2.00

output.L1.power.percent

6.00

output.L2-N.voltage

230.00

output.L2.current

2.70

output.L2.power.percent

8.00

output.L3-N.voltage

229.00

output.L3.current

2.60

output.L3.power.percent

8.00

output.frequency

50.00

output.phases

3.00

ups.firmware.aux


ups.mfr

Net Vision 7 v7.40

ups.model

U4BC02CB00NY100

ups.serial

Pxxxxxxxxx

ups.status

OL

About this device

Reported at:

Further system data or configuration example:

syslog start trace
upsdrvctl[27191]: No matching MIB found for sysOID '.1.3.6.1.4.1.8072.3.2.10'!
upsdrvctl[27191]: Please report it to NUT developers, with an 'upsc' output for your device.
upsdrvctl[27191]: Going back to the classic MIB detection method.
upsdrvctl[27191]: Detected U4BC02CB00NY100 on host 10.10.30.8 (mib: netvision 0.4)
upsdrvctl[27191]: Network UPS Tools - UPS driver controller 2.7.4
snmp-ups[27195]: Startup successful