Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Powercool.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.4.1

Report #1 with driver nutdrv_qx (detailed comments available)

This device is known to work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.voltage

13.80

device.type

ups

driver.flag.norating

enabled

driver.flag.noscanlangid

enabled

driver.flag.novendor

enabled

driver.name

nutdrv_qx

driver.parameter.bus

001

driver.parameter.langid_fix

0x0409

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.productid

0000

driver.parameter.protocol

hunnox

driver.parameter.synchronous

auto

driver.parameter.vendorid

0001

driver.version

2.8.0-rc2

driver.version.data

Hunnox 0.01

driver.version.internal

0.32

driver.version.usb

libusb-1.0.24 (API: 0x1000108)

input.frequency

49.9

input.voltage

240.0

input.voltage.fault

0.0

output.voltage

241.0

ups.beeper.status

disabled

ups.delay.shutdown

60

ups.delay.start

0

ups.load

18

ups.productid

0000

ups.status

OL

ups.temperature

29.0

ups.type

online

ups.vendorid

0001

About this device

Reported at:

Further system data or configuration example:

Driver configuration
[ups]
       driver = nutdrv_qx
       desc = "Powercool 650VA UPS"
       port = "auto"
       vendorid = 0001
       productid = 0000
       bus = 001
       novendor
       norating
       noscanlangid
       protocol=hunnox
       langid_fix = "0x0409"