2.0.4

Report #1 with driver bcmxcp_usb (detailed comments available)

This device is known to work with driver bcmxcp_usb.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.voltage

13.5

driver.name

bcmxcp_usb

driver.parameter.shutdown_delay

90

driver.version

2.0.4

driver.version.internal

0.10

input.frequency

50.1

input.voltage

230

output.current

0.3

output.frequency

50.1

output.voltage

230

ups.firmware

00.50

ups.load

16.7

ups.model

POWERWARE UPS 700VA

ups.power.nominal

700

ups.serial


ups.status

OL

ups.voltage.nominal

240