Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Powerware.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.4

Report #1 with driver bcmxcp (detailed comments available)

This device is known to work with driver bcmxcp.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

ambient.temperature

42

ambient.temperature.high

70

battery.charge

95

battery.charge.restart

76

battery.charger.status

resting

battery.energysave.delay

0

This variable can be set through upsrw to a string value upto the length of 3 characters.

battery.energysave.load

0

This variable can be set through upsrw to a string value upto the length of 3 characters.

battery.packs

1

This variable can be set through upsrw to a string value upto the length of 1 characters.

battery.runtime

2760

battery.runtime.low

2

battery.voltage

52.26

device.mfr

Eaton

device.model

PW5125 1500i

device.part

05146632-5501

device.serial

UX475A0xxxxx

device.type

ups

driver.name

bcmxcp

driver.parameter.baud_rate

9600

driver.parameter.pollinterval

2

driver.parameter.port

/dev/cuaU0

driver.parameter.shutdown_delay

120

driver.parameter.synchronous

no

driver.version

2.7.4

driver.version.internal

0.31

input.frequency

60.08

input.frequency.high

65

input.frequency.low

55

input.frequency.nominal

60

input.transfer.boost.high

108

input.transfer.high

144

input.transfer.low

84

input.transfer.trim.low

127

input.voltage

119

input.voltage.nominal

120

outlet.1.delay.shutdown

-1

This variable can be set through upsrw to a string value upto the length of 5 characters.

outlet.1.delay.start

3

This variable can be set through upsrw to a string value upto the length of 5 characters.

outlet.1.id

1

outlet.1.status

on/closed

outlet.2.delay.shutdown

-1

This variable can be set through upsrw to a string value upto the length of 5 characters.

outlet.2.delay.start

5

This variable can be set through upsrw to a string value upto the length of 5 characters.

outlet.2.id

2

outlet.2.status

on/closed

output.current

0.0

output.current.nominal

13.6

output.frequency

60.08

output.frequency.nominal

60

output.phases

1

output.voltage

119

output.voltage.nominal

120

This variable can be set through upsrw to a string value upto the length of 3 characters.

ups.beeper.status

enabled

ups.description

Line-Interactive UPS, Single Phase

ups.firmware

Cont:01.01 Inve:01.01

ups.load

13.7

ups.mfr

Eaton

ups.model

PW5125 1500i

ups.power

205

ups.power.nominal

1500

ups.realpower

132

ups.serial

UX475A0xxxx

ups.status

OL

ups.test.result

No test initiated

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.mute

  • load.on

  • outlet.1.load.off

  • outlet.1.load.on

  • outlet.1.shutdown.return

  • outlet.2.load.off

  • outlet.2.load.on

  • outlet.2.shutdown.return

  • shutdown.return

  • shutdown.stayoff

  • test.battery.start

2.4.1

Report #1 with driver bcmxcp (detailed comments available)

This device is known to work with driver bcmxcp.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

ambient.temperature

28

ambient.temperature.high

70

battery.charge

98

battery.runtime

2060

battery.voltage

26.95

driver.name

bcmxcp

driver.parameter.baud_rate

9600

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ttyS0

driver.parameter.shutdown_delay

10

driver.version

2.4.1

driver.version.internal

0.21

input.frequency

49.65

input.frequency.high

54

input.frequency.low

46

input.frequency.nominal

50

input.transfer.boost.high

207

input.transfer.high

266

input.transfer.low

171

input.transfer.trim.low

243

input.voltage

234

input.voltage.nominal

230

outlet.1.delay.shutdown

-1

outlet.1.delay.start

1

outlet.1.id

1

outlet.1.status

On

outlet.2.delay.shutdown

-1

outlet.2.delay.start

2

outlet.2.id

2

outlet.2.status

On

output.current

0.0

output.current.nominal

4.5

output.frequency

49.65

output.phases

1

output.voltage

234

output.voltage.nominal

230

ups.beeper.status

enabled

ups.firmware

Cont:02.03 Inve:02.03

ups.load

0.0

ups.model

PW5125 1000VA

ups.power

0

ups.power.nominal

1000

ups.serial

GB282A0427

ups.status

OL

2.2.2

Report #1 with driver bcmxcp (detailed comments available)

This device is known to work with driver bcmxcp.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

ambient.temperature

52

battery.charge

95

battery.runtime

1003

battery.voltage

52.26

driver.name

bcmxcp

driver.parameter.baud_rate

9600

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ttyS0

driver.version

2.2.2

driver.version.internal

0.14

input.frequency

50.00

input.voltage

240

output.current

3.2

output.frequency

50.00

output.phases

1

output.voltage

209

output.voltage.nominal

230

ups.firmware

Cont:01.01 Inve:01.01

ups.load

45.6

ups.model

PW5125 1500VA

ups.power.nominal

1500

ups.serial

UY044A0405

ups.status

TRIM

Fixed in newer versions of NUT to include OL with BYPASS, BOOST, TRIM.