Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Powerware.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.4.1

Report #1 with driver bcmxcp_usb (detailed comments available)

This device is known to work with driver bcmxcp_usb.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

ambient.temperature

40

ambient.temperature.high

40

battery.charge

100

battery.runtime

2610

battery.voltage

54.9

driver.name

bcmxcp_usb

driver.parameter.pollinterval

2

driver.parameter.port

/dev/usb8

driver.parameter.shutdown_delay

120

driver.version

2.4.1

driver.version.internal

0.21

input.frequency

50.0

input.frequency.high

52

input.frequency.low

48

input.frequency.nominal

50

input.transfer.boost.high

176

input.transfer.high

276

input.transfer.low

160

input.transfer.trim.low

254

input.voltage

228

input.voltage.nominal

220

outlet.1.delay.shutdown

-1

This variable can be set through upsrw to a string value.

outlet.1.delay.start

60

This variable can be set through upsrw to a string value.

outlet.1.id

1

outlet.1.status

On

outlet.2.delay.shutdown

-1

This variable can be set through upsrw to a string value.

outlet.2.delay.start

60

This variable can be set through upsrw to a string value.

outlet.2.id

2

outlet.2.status

On

output.current

1.6

output.current.nominal

6.8

output.frequency

50.0

output.phases

1

output.voltage

221

output.voltage.nominal

220

ups.beeper.status

enabled

ups.firmware

Cont:02.05 Inve:02.05

ups.load

22.9

ups.model

PW9120 1500VA

ups.power

344

ups.power.nominal

1500

ups.serial

RY095A0163

ups.status

OL

Known supported commands

This device is known to support the following NUT’s instant commands:

  • outlet.1.shutdown.return

  • outlet.2.shutdown.return

  • shutdown.return

  • shutdown.stayoff

  • test.battery.start

2.2.2

Report #1 with driver snmp-ups (detailed comments available)

This device is known to work with driver snmp-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100.0

battery.runtime

23040.0

battery.runtime.low

2

battery.voltage

26.3

driver.name

snmp-ups

driver.parameter.mibs

ietf

driver.parameter.pollinterval

2

driver.parameter.port

166.99.224.144

driver.version

2.2.2

driver.version.internal

0.421 (mib: ietf 1.2)

input.frequency

50.0

input.phases

1.0

input.voltage

236.0

output.frequency

50.0

output.phases

1.0

output.realpower

0.3

output.voltage

230.0

ups.firmware

FP: 2.60 INV: 2.60

ups.firmware.aux

ConnectUPS Web/SNMP Card V4.26

ups.load

0.0

ups.mfr

Powerware Corporation

ups.model

PW9120

ups.power

3.0

ups.serial

ID: RA384A0447 , Msg: 05147361-5591

ups.status

OL