Report #1 with driver nutdrv_qx (detailed comments available)
This device is known to work with driver nutdrv_qx.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Some more detailed comments are available after the "Known supported…" sections.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.charge
|
|
battery.voltage
|
|
battery.voltage.high
|
|
battery.voltage.low
|
|
battery.voltage.nominal
|
|
device.type
|
|
driver.name
|
|
driver.parameter.offdelay
|
|
driver.parameter.ondelay
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.current.nominal
|
|
input.frequency
|
|
input.frequency.nominal
|
|
input.voltage
|
|
input.voltage.fault
|
|
input.voltage.nominal
|
|
output.voltage
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.delay.start
|
|
ups.firmware.aux
|
|
ups.load
|
|
ups.productid
|
|
ups.status
|
|
ups.type
|
|
ups.vendorid
|
|
About this device
Reported at:
Vendor/Manufacturer information:
Further system data or configuration examples:
upsrw salicru@localhost
listing# TODO: Convert to RW:... and RO:... markup
:; upsrw salicru@localhost
[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: RANGE
Option: "12-540" SELECTED
[ups.delay.start]
Interval to wait before (re)starting the load (seconds)
Type: RANGE
Option: "60-599940" SELECTED
upscmd -l salicru@localhost
listing# TODO: Convert to CMD:... markup
:; upscmd -l salicru@localhost
Instant commands supported on UPS [salicru]:
beeper.toggle - Toggle the UPS beeper
load.off - Turn off the load immediately
load.on - Turn on the load immediately
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress
test.battery.start.quick - Start a quick battery test
Shutdown worked as expected when reaching LOWBATT:
May 13 20:43:22 oriolnas upsmon[1535]: UPS salicru@127.0.0.1 battery is low
May 13 20:43:22 oriolnas upsd[1532]: Client upsmon@127.0.0.1 set FSD on UPS [salicru]
May 13 20:43:22 oriolnas upsmon[1535]: Executing automatic power-fail shutdown
May 13 20:43:22 oriolnas upsmon[1535]: Auto logout and shutdown proceeding