Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Sweex.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.0.5

Report #1 with driver mustek (detailed comments available)

This device is known to work with driver mustek, now replaced by the blazer_ser one. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

80.0

battery.voltage

12.9

driver.name

mustek

driver.parameter.port

/dev/ttyS0

driver.version

2.0.5

driver.version.internal

0.2

input.frequency

50.0

input.voltage

222.8

output.voltage

222.8

ups.load

026

ups.mfr

Mustek

ups.model

PowerMust

ups.status

OL

Report #2 with driver megatec (detailed comments available)

This device is known to work with driver megatec, now replaced by the blazer_ser one. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

80.0

battery.voltage

12.90

battery.voltage.nominal

12.0

driver.name

megatec

driver.parameter.port

/dev/ttyS0

driver.version

2.0.5

driver.version.internal

1.5

input.frequency

49.9

input.voltage

221.9

input.voltage.fault

165.0

input.voltage.maximum

222.0

input.voltage.minimum

221.4

output.voltage

221.9

output.voltage.nominal

220.0

ups.beeper.status

disabled

ups.delay.shutdown

0

ups.delay.start

2

ups.load

26.0

ups.mfr


ups.model

SMART UPS VER:1.00

ups.serial

unknown

ups.status

OL

ups.temperature

28.5

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.toggle

  • load.off

  • load.on

  • reset.input.minmax

  • reset.watchdog

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start

  • test.battery.start.deep

  • test.battery.stop

2.0.1

Report #1 with driver genericups (detailed comments available)

This device is known to work with driver genericups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

driver.name

genericups

driver.parameter.port

/dev/ttyS0

driver.parameter.upstype

7

driver.version

2.0.1

driver.version.internal

1.30

ups.mfr

CyberPower

ups.model

Power99

ups.status

OL