Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Syndome.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.6.4

Report #1 with driver blazer_usb (detailed comments available)

This device is known to work with driver blazer_usb. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.runtime

1000

Not reported by UPS (guesstimate)

battery.voltage

13.60

battery.voltage.high

13.00

battery.voltage.low

10.40

battery.voltage.nominal

12.0

device.type

ups

driver.flag.novendor

enabled

driver.name

blazer_usb

driver.parameter.chargetime

43200

driver.parameter.idleload

30

driver.parameter.pollinterval

5

driver.parameter.port

auto

driver.parameter.productid

5161

driver.parameter.runtimecal

300,100,900,50

Guessed from device rating

driver.parameter.vendorid

0665

driver.version

2.6.4

driver.version.internal

0.08

input.current.nominal

3.0

input.frequency

49.6

input.frequency.nominal

50

input.voltage

234.7

input.voltage.fault

235.2

input.voltage.nominal

220

output.voltage

235.2

ups.beeper.status

enabled

ups.delay.shutdown

30

ups.delay.start

180

ups.load

39

ups.productid

5161

ups.status

OL

ups.temperature

25.0

ups.type

offline / line interactive

ups.vendorid

0665