Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Tripp Lite.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.4.1

Report #1 with driver tripplite_usb (detailed comments available)

This device is known to work with driver tripplite_usb.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.voltage

13.90

battery.voltage.nominal

12

device.mfr

Tripp Lite

device.model

SMX500RT1U

device.type

ups

driver.name

tripplite_usb

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.synchronous

no

driver.version

2.7.4.1

driver.version.internal

0.30

input.voltage

234

input.voltage.maximum

239

input.voltage.minimum

229

input.voltage.nominal

120

outlet.1.desc

Load 1

outlet.1.id

1

outlet.1.switch

1

outlet.1.switchable

1

outlet.2.desc

Load 2

outlet.2.id

2

outlet.2.switchable

0

ups.debug.D

00 ea 00 8b 0d 00 00 '.......'

ups.debug.L

10 00 00 07 58 58 0d '....XX.'

ups.debug.M

00 e5 00 ef 0d 00 00 '.......'

ups.debug.P

30 30 35 30 30 58 0d '00500X.'

ups.debug.S

01 04 00 00 64 00 0d '....d..'

ups.debug.T

29 00 01 f3 00 58 0d '.....X.'

ups.debug.V

06 00 0c 01 58 58 0d '....XX.'

ups.debug.load_banks

1

ups.delay.shutdown

64

ups.firmware

F334403

ups.firmware.aux

protocol 3005

ups.id

0

ups.mfr

Tripp Lite

ups.model

SMX500RT1U

ups.power.nominal

500

ups.productid

0001

ups.status

OL

ups.temperature

0

ups.vendorid

09ae

About this device

Shutdown sequence is a work in progress, but without battery.charge there is no low battery. And the jumping battery voltage levels when the charge gets lower aren’t helping either.

Reported at:

Further system data or configuration example:

Variables per upsrw ups@localhost listing
# TODO: Convert to RW:... and RO:... markup
:; upsrw ups@localhost
[outlet.1.switch]
Outlet switch control
Type: STRING
Maximum length: 3
Value: 1

[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 3
Value: 64

[ups.id]
UPS system identifier
Type: STRING
Maximum length: 5
Value: 0