Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Tripp Lite.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.4

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.runtime

4050

battery.type

PbAC

battery.voltage

13.8

battery.voltage.nominal

12.0

device.mfr

Tripp Lite

device.model

Tripp Lite UPS

device.type

ups

driver.name

usbhid-ups

driver.parameter.bus

001

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.product

Tripp Lite UPS

driver.parameter.productid

2010

driver.parameter.synchronous

no

driver.parameter.vendor

Tripp Lite

driver.parameter.vendorid

09AE

driver.version

2.7.4

driver.version.data

TrippLite HID 0.82

driver.version.internal

0.41

input.frequency

60.1

input.voltage

119.8

input.voltage.nominal

120

output.frequency.nominal

60

output.voltage.nominal

120

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.mfr

Tripp Lite

ups.model

Tripp Lite UPS

ups.power.nominal

550

ups.productid

2010

ups.status

OL

ups.test.result

Done and passed

ups.timer.reboot

65535

ups.timer.shutdown

65535

ups.vendorid

09ae

ups.watchdog.status

0

About this device

Device dump generated by ./nut-ddl-dump.sh on Mon, 08 Aug 2022 10:49:04 -0400

Further system data or configuration examples:

Variables per upsrw Smart550USB@localhost listing
# TODO: Convert to RW:... and RO:... markup
:; upsrw Smart550USB@localhost
[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 10
Value: 20
Commands per upscmd -l Smart550USB@localhost listing
# TODO: Convert to CMD:... markup
:; upscmd -l Smart550USB@localhost
Instant commands supported on UPS [Smart550USB]:

beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
reset.watchdog - Reset watchdog timer
shutdown.reboot - Shut down the load briefly while rebooting the UPS
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test