|   | When a user reports that a variable/command is not right then it will be highlighted by a red underline. Bad values/ranges/etc… will get a red dashed outline or red solid left border. The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left. | 
2.7.2
Report #1 with driver usbhid-ups (detailed comments available)
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev file to simulate this device clicking here.
Some more detailed comments are available after the "Known supported…" sections.
Known supported variables
This device is known to support the following variables (values are just examples):
| battery.charge | 
 | 
| battery.charge.low | 
 | 
| battery.charge.warning | 
 | 
| battery.date | 
 | 
| battery.runtime | 
 | 
| battery.type | 
 | 
| device.mfr | 
 | 
| device.model | 
 | 
| device.serial | 
 | 
| device.type | 
 | 
| driver.name | 
 | 
| driver.parameter.pollfreq | 
 | 
| driver.parameter.pollinterval | 
 | 
| driver.parameter.port | 
 | 
| driver.parameter.vendorid | 
 | 
| driver.version | 
 | 
| driver.version.data | 
 | 
| driver.version.internal | 
 | 
| input.frequency | 
 | 
| input.voltage | 
 | 
| input.voltage.nominal | 
 | 
| output.frequency | 
 | 
| output.voltage | 
 | 
| output.voltage.nominal | 
 | 
| ups.beeper.status | 
 | 
| ups.date | 
 | 
| ups.delay.shutdown | 
 | 
| ups.delay.start | 
 | 
| ups.load | 
 | 
| ups.mfr | 
 | 
| ups.model | 
 | 
| ups.productid | 
 | 
| ups.serial | 
 | 
| ups.status | 
 | 
| ups.test.result | 
 | 
| ups.timer.shutdown | 
 | 
| ups.timer.start | 
 | 
| ups.vendorid | 
 | 
About this device
Sometimes ups.beeper.status: disabled disappears from upsc output after
invoking beeper.disable or beeper.enable command, but the commands are
processed as expected. ups.beeper.status never shown as enabled in upsc
report.
When UPS in warning state, beeper.disable does not disable beeper.
Beeper could be disabled in this mode only by hardware button.
Setting battery charge works with config file (because upsrw errors out)
as in the attached example.
See also comments for Raptor 2000 with similar issues.
- 
Notification with COMMBAD driver restart 
|   | This UPS occasionally disconnects, and driver begins reporting "Data Stale" As a workaround, in  Populate the notification script like this:
 Configure the driver like this:
  | 
Reported at:
Vendor/Manufacturer information:
Further system data or configuration examples:
[RPT-600AP]
       # Setting battery charge works with config file
       # (because `upsrw` errors out)
       driver = usbhid-ups
       port = auto
       vendorid = 0d9f
       ignorelb
       override.battery.charge.low = 70
       override.battery.charge.warning = 80upsrw RPT-600AP@localhost listing# TODO: Convert to RW:... and RO:... markup
:; upsrw RPT-600AP@localhost
[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 8
Value: 20
[ups.delay.start]
Interval to wait before (re)starting the load (seconds)
Type: STRING
Maximum length: 8
Value: 60upscmd -l RPT-600AP@localhost listing# TODO: Convert to CMD:... markup
:; upscmd -l RPT-600AP@localhost
Instant commands supported on UPS [RPT-600AP]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.toggle - Toggle the UPS beeper
load.on - Turn on the load immediately
load.on.delay - Turn on the load with a delay (seconds)
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
test.battery.start.quick - Start a quick battery testlsusb listing:; lsusb -d 0d9f:0004 -v
Bus 002 Device 002: ID 0d9f:0004 Powercom Co., Ltd
Device Descriptor:
  bLength                18
  bDescriptorType         1
  bcdUSB               1.10
  bDeviceClass            0 (Defined at Interface level)
  bDeviceSubClass         0
  bDeviceProtocol         0
  bMaxPacketSize0         8
  idVendor           0x0d9f Powercom Co., Ltd
  idProduct          0x0004
  bcdDevice            0.02
  iManufacturer           3 POWERCOM Co.,LTD
  iProduct                1 HID UPS Battery
  iSerial                 2 004-0D9F-000
  bNumConfigurations      1
  Configuration Descriptor:
    bLength                 9
    bDescriptorType         2
    wTotalLength           34
    bNumInterfaces          1
    bConfigurationValue     1
    iConfiguration          0
    bmAttributes         0xa0
      (Bus Powered)
      Remote Wakeup
    MaxPower              100mA
    Interface Descriptor:
      bLength                 9
      bDescriptorType         4
      bInterfaceNumber        0
      bAlternateSetting       0
      bNumEndpoints           1
      bInterfaceClass         3 Human Interface Device
      bInterfaceSubClass      0 No Subclass
      bInterfaceProtocol      0 None
      iInterface              0
        HID Device Descriptor:
          bLength                 9
          bDescriptorType        33
          bcdHID               1.00
          bCountryCode            0 Not supported
          bNumDescriptors         1
          bDescriptorType        34 Report
          wDescriptorLength     996
         Report Descriptors:
           ** UNAVAILABLE **
      Endpoint Descriptor:
        bLength                 7
        bDescriptorType         5
        bEndpointAddress     0x81  EP 1 IN
        bmAttributes            3
          Transfer Type            Interrupt
          Synch Type               None
          Usage Type               Data
        wMaxPacketSize     0x0008  1x 8 bytes
        bInterval             100
Device Status:     0x0001
  Self Powered