Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from AEG Power Solutions.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.6.1

Report #1

This device is known to work with driver blazer_usb. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.voltage

13.60

battery.voltage.nominal

12.0

beeper.status

enabled

device.type

ups

driver.name

blazer_usb

driver.parameter.pollinterval

2

driver.parameter.port

/dev/hidraw_protecthome

driver.version

2.6.1

driver.version.internal

0.03

input.current.nominal

2.0

input.frequency

49.9

input.frequency.nominal

50

input.voltage

241.4

input.voltage.fault

241.4

input.voltage.nominal

230

output.voltage

237.5

ups.delay.shutdown

30

ups.delay.start

180

ups.load

4

ups.productid

5161

ups.status

OL

ups.temperature

25.0

ups.type

offline / line interactive

ups.vendorid

0665