Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.date

2010/09/19

battery.mfr.date

2010/09/19

battery.runtime

3877

battery.runtime.low

120

battery.temperature

29.2

battery.type

PbAc

battery.voltage

13.6

battery.voltage.nominal

12.0

device.mfr

American Power Conversion

device.model

Back-UPS CS 500

device.serial

4B1038P51197

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.6.0

driver.version.data

APC HID 0.95

driver.version.internal

0.35

input.sensitivity

medium

input.voltage

224.0

input.voltage.nominal

230

output.voltage

230.0

output.voltage.nominal

230.0

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.firmware

808.q10 .I

ups.firmware.aux

q10

ups.load

0.0

ups.mfr

American Power Conversion

ups.mfr.date

2010/09/19

ups.model

Back-UPS CS 500

ups.productid

0002

ups.serial

4B1038P51197

ups.status

OL

ups.test.result

No test initiated

ups.timer.reboot

0

ups.timer.shutdown

-1

ups.timer.start

0

ups.vendorid

051d

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.mute

  • beeper.off

  • beeper.on

  • load.off

  • load.off.delay

  • load.on

  • load.on.delay

  • shutdown.reboot

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop

  • test.panel.start

  • test.panel.stop