Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from APC.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.2.2

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.date

2007/02/13

battery.mfr.date

2007/02/13

battery.runtime

1290

battery.runtime.low

120

battery.temperature

29.2

battery.type

PbAc

battery.voltage

13.5

battery.voltage.nominal

12.0

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.2.2

driver.version.data

APC HID 0.92

driver.version.internal

0.33

input.voltage

214.0

input.voltage.nominal

230

output.voltage

230.0

output.voltage.nominal

230.0

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.firmware

817.v4.I

ups.firmware.aux

v4

ups.load

25.0

ups.mfr

American Power Conversion

ups.mfr.date

2007/02/13

ups.model

Back-UPS CS 650

ups.productid

0002

ups.serial

QB0707231626

ups.status

OL

ups.test.result

No test initiated

ups.timer.reboot

0

ups.timer.shutdown

-1

ups.vendorid

051d

2.0.5

Report #1

This device is known to work with driver newhidups, now replaced by the usbhid-ups one.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.date

2007/02/13

battery.mfr.date

2007/02/13

battery.runtime

1215

battery.runtime.low

120

battery.temperature

28

battery.type

PbAc

battery.voltage

13.5

battery.voltage.nominal

12.0

driver.name

newhidups

driver.parameter.port

/dev/ttyS1

driver.version

2.0.5

driver.version.data

APC/CyberPower HID 0.9

driver.version.internal

0.30

input.voltage

204.0

input.voltage.nominal

230

output.voltage

230.0

output.voltage.nominal

230.0

ups.beeper.status

enabled

ups.delay.shutdown

-1

ups.firmware

817.v4.I

ups.firmware.aux

v4

ups.load

25.0

ups.mfr

American Power Conversion

ups.mfr.date

2007/02/13

ups.model

Back-UPS CS 650

ups.power.nominal

566

ups.serial

QB0707231626

ups.status

OL

ups.test.result

No test initiated