This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.date

2001/09/25

battery.mfr.date

2007/07/26

battery.runtime

6922

battery.runtime.low

120

battery.temperature

29.2

battery.type

PbAc

battery.voltage

27.4

battery.voltage.nominal

24.0

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.2.2

driver.version.data

APC HID 0.92

driver.version.internal

0.33

input.voltage

228.0

input.voltage.nominal

230

output.voltage

230.0

output.voltage.nominal

230.0

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.firmware

9.o4 .I

ups.firmware.aux

o4

ups.load

0.0

ups.mfr

American Power Conversion

ups.mfr.date

2007/07/26

ups.model

Back-UPS BR 800

ups.productid

0002

ups.serial

***

ups.status

OL

ups.test.result

No test initiated

ups.timer.reboot

0

ups.timer.shutdown

-1

ups.vendorid

051d

Report #2

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.date

2001/09/25

battery.mfr.date

2007/12/28

battery.runtime

997

battery.runtime.low

120

battery.temperature

3022999999999999855

Clearly bogus value; fixed in newer versions of NUT.

battery.type

PbAc

battery.voltage

27.8

battery.voltage.nominal

24.0

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.2.2

driver.version.data

APC HID 0.92

driver.version.internal

0.33

input.voltage

232.0

input.voltage.nominal

230

output.voltage

230.0

output.voltage.nominal

230.0

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.firmware

9.o4 .I

ups.firmware.aux

o4

ups.load

460000000000000000522694688304941003169920226853844164973253026123689780561201643569637208248542908198527766044790898610404968516009252686779106462679232958642106465178573742621663105573836478844157360968769427943324469938758039552774256898399191695594881

Clearly bogus value; fixed in newer versions of NUT.

ups.mfr

American Power Conversion

ups.mfr.date

2007/12/28

ups.model

Back-UPS BR 800

ups.productid

0002

ups.serial

[hidden]

ups.status

OL

ups.test.result

No test initiated

ups.timer.reboot

0

ups.timer.shutdown

-1

ups.vendorid

051d

2.2.1

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.date

2001/09/25

battery.mfr.date

2007/11/25

battery.runtime

2460

battery.runtime.low

120

battery.temperature

28

battery.type

PbAc

battery.voltage

27.4

battery.voltage.nominal

24.0

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

/dev/usb/hiddev0

driver.version

2.2.1

driver.version.data

APC HID 0.92

driver.version.internal

0.32

input.voltage

238.0

input.voltage.nominal

230

output.voltage

230.0

output.voltage.nominal

230.0

ups.beeper.status

disabled

ups.delay.shutdown

-1

ups.firmware

9.o4 .I

ups.firmware.aux

o4

ups.load

26.0

ups.mfr

American Power Conversion

ups.mfr.date

2007/11/25

ups.model

Back-UPS BR 800

ups.productid

0002

ups.serial

[hidden]

ups.status

OL

ups.test.result

No test initiated

ups.vendorid

051d

2.0.2

Report #1

This device is known to work with driver hidups, now replaced by the usbhid-ups one.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.chemistry

PbAc

battery.runtime

1162

battery.voltage

27.4

driver.name

hidups

driver.parameter.port

/dev/usb/hiddev0

driver.version

2.0.2

ups.delay.shutdown

-1

ups.delay.start

0

ups.load

410

ups.mfr

American Power Conversion

ups.model

Back-UPS BR 800 FW:9.o2 .I USB FW:o2

ups.serial

QB0420243302

ups.status

OL

Report #2

This device is known to work with driver newhidups, now replaced by the usbhid-ups one.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.runtime

1192

battery.temperature

302.0

battery.voltage

27.0

battery.voltage.nominal

24.0

driver.name

newhidups

driver.parameter.port

/dev/usb/hiddev0

driver.version

2.0.2

driver.version.data

APC HID 0.7

driver.version.internal

0.23

input.voltage

-159357104.0

output.voltage

230.0

output.voltage.target.line

230.0

ups.delay.shutdown

-1

ups.firmware

9.o2 .I

ups.firmware.aux

o2

ups.load

40

ups.mfr

American Power Conversion

ups.model

Back-UPS BR 800

ups.serial

QB0420243302

ups.status

OL

ups.temperature

302.0

ups.test.result

No test initiated