Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from APC.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.2.0

Report #1

This device is known to work with driver apcsmart.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

driver.name

apcsmart

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ttyS0

driver.version

2.2.0-

driver.version.internal

1.99.8

input.voltage

231.8

output.current

09.31

ups.mfr

APC

ups.model

Matrix-UPS

ups.serial

********

ups.status

OL

Report #2

This device is known to work with driver apcsmart.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.alarm.threshold

L

battery.charge

100.0

battery.charge.restart

00

battery.date

04/07/03

battery.packs

003

battery.packs.bad

000

battery.runtime

22560

battery.runtime.low

600

battery.voltage

55.36

battery.voltage.nominal

048

driver.name

apcsmart

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ttyS0

driver.version

2.2.0

driver.version.internal

1.99.8

input.frequency

50.00

input.quality

FF

input.sensitivity

H

input.transfer.high

264

input.transfer.low

176

input.transfer.reason

T

input.voltage

231.8

input.voltage.maximum

231.8

input.voltage.minimum

231.8

output.current

05.43

output.voltage

239.3

output.voltage.nominal

230

ups.delay.shutdown

180

ups.delay.start

000

ups.id

UPS_IDEN

ups.load

039.0

ups.mfr

APC

ups.mfr.date

10/18/99

ups.model

Smart-UPS

ups.serial

********

ups.status

OL

ups.temperature

021.6

ups.test.interval

1209600

ups.test.result

NO

1.4.0

Report #1

This device is known to work with driver apcsmart.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.alarm.threshold

0

battery.charge

100.0

battery.charge.restart

00

battery.date

10/25/93

battery.voltage

55.62

driver.name

apcsmart

driver.parameter.port

/dev/ttyS0

driver.version

1.4.0

driver.version.internal

0.72

input.frequency

50.00

input.sensitivity

A

input.transfer.high

253

input.transfer.low

176

input.voltage

233.7

output.voltage

226.2

ups.delay.shutdown

600

ups.delay.start

000

ups.id

79<><>/\

ups.load

049.4

ups.mfr

APC

ups.model

Matrix-UPS

ups.serial

********

ups.status

OL

ups.temperature

022.5