2.6.0

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.mfr.date

2007/07/07

battery.runtime

6300

battery.runtime.low

120

battery.temperature

31.5

battery.type

PbAc

battery.voltage

27.4

battery.voltage.nominal

24.0

device.mfr

American Power Conversion

device.model

Smart-UPS 1000

device.serial

AS0727233122

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.6.0

driver.version.data

APC HID 0.95

driver.version.internal

0.35

input.sensitivity

high

input.voltage

226.0

output.voltage

226.0

output.voltage.nominal

230.0

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.delay.start

30

ups.firmware

652.13.I

ups.firmware.aux

7.3

ups.load

5.2

ups.mfr

American Power Conversion

ups.mfr.date

2007/07/07

ups.model

Smart-UPS 1000

ups.productid

0002

ups.serial

AS0727233122

ups.status

OL

ups.test.result

No test initiated

ups.timer.reboot

-1

ups.timer.shutdown

-1

ups.timer.start

-1

ups.vendorid

051d

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.mute

  • beeper.off

  • beeper.on

  • load.off

  • load.off.delay

  • load.on

  • load.on.delay

  • shutdown.reboot

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop

  • test.panel.start

  • test.panel.stop

2.4.1

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.mfr.date

2007/07/07

battery.runtime

5880

battery.runtime.low

120

battery.temperature

31.5

battery.type

PbAc

battery.voltage

27.4

battery.voltage.nominal

24.0

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.4.1

driver.version.data

APC HID 0.93

driver.version.internal

0.34

input.voltage

224.6

output.voltage

224.6

output.voltage.nominal

230.0

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.firmware

652.13.I

ups.firmware.aux

7.3

ups.load

5.8

ups.mfr

American Power Conversion

ups.mfr.date

2007/07/07

ups.model

Smart-UPS 1000

ups.productid

0002

ups.serial

AS0727233122

ups.status

OL

ups.test.result

No test initiated

ups.timer.reboot

-1

ups.timer.shutdown

-1

ups.vendorid

051d

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.mute

  • beeper.off

  • beeper.on

  • load.off

  • load.off.delay

  • load.on

  • load.on.delay

  • shutdown.reboot

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop

  • test.panel.start

  • test.panel.stop

Report #2

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.mfr.date

2007/11/18

battery.runtime

2940

battery.runtime.low

120

battery.temperature

34.2

battery.type

PbAc

battery.voltage

27.3

battery.voltage.nominal

24.0

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

/dev/usb/hiddev0

driver.version

2.4.1

driver.version.data

APC HID 0.93

driver.version.internal

0.34

input.voltage

216.0

output.voltage

216.0

output.voltage.nominal

220.0

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.firmware

652.18.I

ups.firmware.aux

7.3

ups.load

26.0

ups.mfr

American Power Conversion

ups.mfr.date

2007/11/18

ups.model

Smart-UPS 1000

ups.productid

0002

ups.serial

AS0746224745

ups.status

OL

ups.test.result

No test initiated

ups.timer.reboot

-1

ups.timer.shutdown

-1

ups.vendorid

051d