2.7.2

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

93

battery.charge.low

10

battery.charge.warning

50

battery.mfr.date

2006/04/01

battery.runtime

2220

battery.runtime.low

120

battery.temperature

30.6

battery.type

PbAc

battery.voltage

27.4

battery.voltage.nominal

24.0

device.mfr

American Power Conversion

device.model

Smart-UPS 1500

device.serial

AS0614322014

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.7.2

driver.version.data

APC HID 0.95

driver.version.internal

0.38

input.sensitivity

high

input.transfer.high

127

input.transfer.low

106

input.transfer.reason

input voltage out of range

input.voltage

121.6

output.frequency

60.0

output.voltage

121.6

output.voltage.nominal

120.0

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.firmware

601.3.D

ups.firmware.aux

1.5

ups.load

32.5

ups.mfr

American Power Conversion

ups.mfr.date

2006/04/01

ups.model

Smart-UPS 1500

ups.productid

0002

ups.serial

AS0614322014

ups.status

OL

ups.test.result

No test initiated

ups.timer.reboot

-1

ups.timer.shutdown

-1

ups.timer.start

-1

ups.vendorid

051d

2.6.4

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

50

battery.mfr.date

2008/05/22

battery.runtime

3420

battery.runtime.low

120

battery.temperature

24.7

battery.type

PbAc

battery.voltage

27.7

battery.voltage.nominal

24.0

device.mfr

American Power Conversion

device.model

Smart-UPS 1500

device.serial

AS0821131402

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.6.4

driver.version.data

APC HID 0.95

driver.version.internal

0.37

input.sensitivity

high

input.transfer.high

253

input.transfer.low

208

input.voltage

231.8

output.current

1.05

output.frequency

50.0

output.voltage

231.8

output.voltage.nominal

230.0

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.firmware

653.18.I

ups.firmware.aux

7.3

ups.load

22.7

ups.mfr

American Power Conversion

ups.mfr.date

2008/05/22

ups.model

Smart-UPS 1500

ups.productid

0002

ups.serial

AS0821131402

ups.status

OL

ups.test.result

No test initiated

ups.timer.reboot

-1

ups.timer.shutdown

-1

ups.timer.start

-1

ups.vendorid

051d

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.mute

  • beeper.off

  • beeper.on

  • load.off

  • load.off.delay

  • load.on

  • load.on.delay

  • shutdown.reboot

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop

  • test.panel.start

  • test.panel.stop

2.2.1

Report #1

This device is known to work with driver apcsmart.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.alarm.threshold

0

battery.charge

100.0

battery.charge.restart

00

battery.date

09/06/05

battery.packs

000

battery.runtime

3720

battery.runtime.low

120

battery.voltage

27.40

battery.voltage.nominal

024

driver.name

apcsmart

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ttyS0

driver.parameter.sdtype

0

driver.version

2.2.1-

driver.version.internal

1.99.8

input.frequency

50.00

input.quality

FF

input.sensitivity

H

input.transfer.high

253

input.transfer.low

208

input.transfer.reason

S

input.voltage

236.1

input.voltage.maximum

236.1

input.voltage.minimum

233.2

output.voltage

236.1

output.voltage.nominal

230

ups.delay.shutdown

090

ups.delay.start

000

ups.firmware

601.3.I

ups.id

UPS_IDEN

ups.load

004.5

ups.mfr

APC

ups.mfr.date

09/06/05

ups.model

Smart-UPS 1500

ups.serial

AS0537230534(

ups.status

OL

ups.temperature

031.0

ups.test.interval

1209600

ups.test.result

NO

About this device

The commands to shutdown the UPS don’t seem to work: shutdown.stayoff, shutdown.return and load.off all seem to silently do nothing.