Report #1
This device is known to work with driver apcsmart.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.alarm.threshold
|
This variable can be set through upsrw to one of the following values:
|
battery.charge
|
|
battery.charge.restart
|
This variable can be set through upsrw to one of the following values:
|
battery.date
|
This variable can be set through upsrw to a string value. |
battery.runtime
|
|
battery.runtime.low
|
This variable can be set through upsrw to one of the following values:
|
battery.voltage
|
|
battery.voltage.nominal
|
|
device.mfr
|
|
device.model
|
|
device.serial
|
|
device.type
|
|
driver.name
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.version
|
|
driver.version.internal
|
|
input.frequency
|
|
input.quality
|
|
input.sensitivity
|
This variable can be set through upsrw to one of the following values:
|
input.transfer.high
|
This variable can be set through upsrw to one of the following values:
|
input.transfer.low
|
This variable can be set through upsrw to one of the following values:
|
input.transfer.reason
|
|
input.voltage
|
|
input.voltage.maximum
|
|
input.voltage.minimum
|
|
output.voltage
|
|
output.voltage.nominal
|
|
ups.delay.shutdown
|
This variable can be set through upsrw to one of the following values:
|
ups.delay.start
|
This variable can be set through upsrw to one of the following values:
|
ups.firmware
|
|
ups.firmware.old
|
|
ups.id
|
This variable can be set through upsrw to a string value. |
ups.load
|
|
ups.mfr
|
|
ups.mfr.date
|
|
ups.model
|
|
ups.serial
|
|
ups.status
|
|
ups.test.interval
|
This variable can be set through upsrw to one of the following values:
|
ups.test.result
|
|
Known supported commands
This device is known to support the following NUT’s instant commands:
-
calibrate.start
-
calibrate.stop
-
load.off
-
load.on
-
shutdown.return
-
shutdown.return.grace
-
shutdown.stayoff
-
test.battery.start
-
test.battery.stop
-
test.failure.start
-
test.panel.start