2.7.4

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

This variable can be set through upsrw to a string value upto the length of 10 characters.

battery.charge.warning

20

battery.mfr.date

CPS

battery.runtime

2902

battery.runtime.low

300

This variable can be set through upsrw to a string value upto the length of 10 characters.

battery.type

PbAcid

battery.voltage

26.9

battery.voltage.nominal

24

device.mfr

CPS

device.model

CP1500AVRLCDa

device.serial

CTHGN200xxxx

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.product

CP1500AVRLCDa

driver.parameter.productid

0501

driver.parameter.serial

CTHGN200xxxx

driver.parameter.synchronous

no

driver.parameter.vendorid

0764

driver.version

2.7.4

driver.version.data

CyberPower HID 0.4

driver.version.internal

0.41

input.voltage

121.0

input.voltage.nominal

120

output.voltage

137.0

ups.beeper.status

enabled

ups.delay.shutdown

20

This variable can be set through upsrw to a string value upto the length of 10 characters.

ups.delay.start

30

This variable can be set through upsrw to a string value upto the length of 10 characters.

ups.load

18

ups.mfr

CPS

ups.model

CP1500AVRLCDa

ups.productid

0501

ups.realpower.nominal

900

ups.serial

CTHGN200xxxx

ups.status

OL

ups.test.result

No test initiated

ups.timer.shutdown

-60

ups.timer.start

-60

ups.vendorid

0764

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.mute

  • beeper.off

  • beeper.on

  • load.off

  • load.off.delay

    delay values seem to be rounded down to multiples of 60 seconds; 0—59 yield no delay at all

  • load.on

  • load.on.delay

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop