Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Cyber Power Systems.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.2.1

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.charge.warning

20

battery.mfr.date

CPS

battery.runtime

1050

battery.runtime.low

300

battery.type

PbAcid

battery.voltage

21.2

battery.voltage.nominal

12

driver.name

usbhid-ups

driver.parameter.bus

233

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.2.1-

driver.version.data

CyberPower HID 0.1

driver.version.internal

0.32

input.transfer.high

280

input.transfer.low

180

input.voltage

233.0

input.voltage.nominal

230

output.voltage

233.0

ups.beeper.status

enabled

ups.load

25

ups.mfr

CPS

ups.model

UPS VALUE

ups.productid

0501

ups.realpower.nominal

480

ups.status

OL

ups.vendorid

0764