Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Eaton.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.1

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

35

battery.runtime

1076

battery.type

PbAc

device.mfr

EATON

device.model

5E 650i

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.7.1

driver.version.data

MGE HID 1.32

driver.version.internal

0.38

input.voltage

247.0

outlet.1.status

on

outlet.desc

Main Outlet

outlet.id

1

outlet.switchable

no

output.frequency

50.0

output.frequency.nominal

50

output.voltage

246.0

output.voltage.nominal

230

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.firmware

01.04.0016

ups.load

11

ups.mfr

EATON

ups.model

5E 650i

ups.power.nominal

650

ups.productid

ffff

ups.start.battery

yes

ups.status

OL CHRG

ups.timer.shutdown

-1

ups.vendorid

0463

Report #2

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.runtime

2520

battery.type

PbAc

device.mfr

EATON

device.model

5E 650i

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.7.1

driver.version.data

MGE HID 1.32

driver.version.internal

0.38

input.voltage

247.0

outlet.1.status

on

outlet.desc

Main Outlet

This variable can be set through upsrw to a string value upto the length of 20 characters.

outlet.id

1

outlet.switchable

no

output.frequency

49.8

output.frequency.nominal

50

output.voltage

244.0

output.voltage.nominal

230

This variable can be set through upsrw to one of the following values:

  • 200

  • 208

  • 220

  • 230

  • 240

ups.beeper.status

enabled

ups.delay.shutdown

20

This variable can be set through upsrw to a string value upto the length of 10 characters.

ups.firmware

01.04.0016

ups.load

14

ups.mfr

EATON

ups.model

5E 650i

ups.power.nominal

650

ups.productid

ffff

ups.start.battery

yes

This variable can be set through upsrw to a string value upto the length of 5 characters.

ups.status

OL CHRG

ups.timer.shutdown

-1

ups.vendorid

0463

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.mute

  • beeper.off

  • beeper.on

  • load.off

  • load.off.delay

  • shutdown.stop