Click here to see reports of other supported models from Eaton.
When a user reports that a variable/command is not right then it will be highlighted by a red underline. Bad values/ranges/etc… will get a red dashed outline or red solid left border. The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left. |
2.7.4
Report #1
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.capacity
|
|
battery.charge
|
|
battery.charge.low
|
This variable can be set through upsrw to a string value upto the length of |
battery.charge.restart
|
This variable can be set through upsrw to a string value upto the length of |
battery.charger.status
|
|
battery.energysave
|
This variable can be set through upsrw to a string value upto the length of |
battery.protection
|
This variable can be set through upsrw to a string value upto the length of |
battery.runtime
|
|
battery.type
|
|
device.mfr
|
|
device.model
|
|
device.serial
|
|
device.type
|
|
driver.name
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.parameter.synchronous
|
|
driver.parameter.vendorid
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.current
|
|
input.frequency
|
|
input.frequency.extended
|
This variable can be set through upsrw to a string value upto the length of |
input.frequency.nominal
|
|
input.sensitivity
|
This variable can be set through upsrw to a string value upto the length of |
input.transfer.boost.low
|
This variable can be set through upsrw to a string value upto the length of |
input.transfer.high
|
This variable can be set through upsrw to a string value upto the length of |
input.transfer.low
|
This variable can be set through upsrw to a string value upto the length of |
input.transfer.trim.high
|
This variable can be set through upsrw to a string value upto the length of |
input.voltage
|
|
input.voltage.extended
|
This variable can be set through upsrw to a string value upto the length of |
input.voltage.nominal
|
|
outlet.1.autoswitch.charge.low
|
This variable can be set through upsrw to a string value upto the length of |
outlet.1.current
|
|
outlet.1.delay.shutdown
|
This variable can be set through upsrw to a string value upto the length of |
outlet.1.delay.start
|
This variable can be set through upsrw to a string value upto the length of |
outlet.1.desc
|
This variable can be set through upsrw to a string value upto the length of |
outlet.1.id
|
|
outlet.1.power
|
|
outlet.1.powerfactor
|
|
outlet.1.realpower
|
|
outlet.1.status
|
|
outlet.1.switchable
|
|
outlet.2.autoswitch.charge.low
|
This variable can be set through upsrw to a string value upto the length of |
outlet.2.current
|
|
outlet.2.delay.shutdown
|
This variable can be set through upsrw to a string value upto the length of |
outlet.2.delay.start
|
This variable can be set through upsrw to a string value upto the length of |
outlet.2.desc
|
This variable can be set through upsrw to a string value upto the length of |
outlet.2.id
|
|
outlet.2.power
|
|
outlet.2.powerfactor
|
|
outlet.2.realpower
|
|
outlet.2.status
|
|
outlet.2.switchable
|
|
outlet.current
|
|
outlet.desc
|
This variable can be set through upsrw to a string value upto the length of |
outlet.id
|
|
outlet.power
|
|
outlet.powerfactor
|
|
outlet.realpower
|
|
outlet.switchable
|
|
output.current
|
|
output.frequency
|
|
output.frequency.nominal
|
|
output.powerfactor
|
|
output.voltage
|
|
output.voltage.nominal
|
This variable can be set through upsrw to one of the following values:
|
ups.alarm
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
This variable can be set through upsrw to a string value upto the length of |
ups.delay.start
|
This variable can be set through upsrw to a string value upto the length of |
ups.efficiency
|
|
ups.firmware
|
|
ups.load
|
|
ups.load.high
|
This variable can be set through upsrw to a string value upto the length of |
ups.mfr
|
|
ups.model
|
|
ups.power
|
|
ups.power.nominal
|
|
ups.productid
|
|
ups.realpower
|
|
ups.realpower.nominal
|
|
ups.serial
|
|
ups.shutdown
|
This variable can be set through upsrw to one of the following values:
|
ups.start.auto
|
This variable can be set through upsrw to a string value upto the length of |
ups.start.battery
|
This variable can be set through upsrw to a string value upto the length of |
ups.start.reboot
|
This variable can be set through upsrw to a string value upto the length of |
ups.status
|
|
ups.test.interval
|
This variable can be set through upsrw to a string value upto the length of |
ups.test.result
|
|
ups.timer.shutdown
|
|
ups.timer.start
|
|
ups.type
|
|
ups.vendorid
|
|
Known supported commands
This device is known to support the following NUT’s instant commands:
-
beeper.disable
-
beeper.enable
-
beeper.mute
-
beeper.off
-
beeper.on
-
load.off
-
load.off.delay
-
load.on
-
load.on.delay
-
outlet.1.load.off
-
outlet.1.load.on
-
outlet.2.load.off
-
outlet.2.load.on
-
shutdown.return
-
shutdown.stayoff
-
shutdown.stop
-
test.battery.start.deep
-
test.battery.start.quick
-
test.battery.stop