2.6.0

Report #1

This device is known to work with driver blazer_ser. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.voltage

27.10

battery.voltage.nominal

23.5

beeper.status

disabled

device.mfr

KONIG COMPUTER

device.model

CMP1200

device.type

ups

driver.name

blazer_ser

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ttyD0

driver.version

2.6.0

driver.version.internal

1.51

input.current.nominal

6.0

input.frequency

50.0

input.frequency.nominal

50

input.voltage

226.0

input.voltage.fault

165.0

input.voltage.nominal

220

output.voltage

226.0

ups.alarm

Shutdown imminent!

ups.delay.shutdown

30

ups.delay.start

180

ups.firmware

VER4.00C

ups.load

0

ups.mfr

KONIG COMPUTER

ups.model

CMP1200

ups.status

ALARM OL

ups.temperature

0.0

ups.type

offline / line interactive